Why the study?
Does intramural injection of hydrocortisone-loaded microspheres reduce intimal hyperplasia in a rabbit model of balloon angioplasty?
Does intramural injection of hydrocortisone-loaded microspheres reduce intimal hyperplasia in a rabbit model of balloon angioplasty?
Local delivery of hydrocortisone via biodegradable microspheres significantly reduces intimal hyperplasia after balloon angioplasty in a rabbit model.
Hypothesis-generating for local steroid delivery in restenosis; human trials required before clinical consideration.
Restenosis remains the major limitation of coronary angioplasty. The objective of this study was to develop microspheres able to be delivered at the angioplasty site for long-term drug release and to test their effects in a model of balloon angioplasty. Polylactic-co-glycolide acid microspheres (5-10 microm in diameter) were prepared by using an oil-in-water emulsion-solvent evaporation method. In vitro experiments with hydrocortisone-loaded microspheres revealed a hydrocortisone release for 4 weeks. We studied the in vivo effect of injection of microspheres into the arterial wall of New Zealand White rabbits by using a perforated balloon. Deep penetration of microspheres in the arterial wall was documented immediately after angioplasty. Intimal hyperplasia was assessed in iliac arteries 4 weeks after angioplasty. The morphometric analysis was performed in four groups of animals; the first group was subjected only to conventional angioplasty (control, n = 10), whereas the other three groups after conventional angioplasty were received perforated balloon angioplasty with saline (n = 10), microspheres (n = 10), or hydrocortisone-loaded microspheres (n = 7). Intramural injection of saline did not induce greater intimal hyperplasia compared with control (0.17 +/- 0.03 vs. 0.18 +/- 0.03 mm2, respectively). Microspheres injection was associated with a trend toward a greater degree of intimal hyperplasia that did not reach statistical significance. Hydrocortisone-loaded microspheres were associated with a significant reduction in intimal hyperplasia compared with unloaded microspheres (0.16 +/- 0.02 vs. 0.26 +/- 0.03 mm2, respectively). The polylactic-co-glycolide acid microspheres are well tolerated, easily injected into the arterial wall, and the increase of intimal hyperplasia is easily inhibited by release of hydrocortisone for 4 weeks after initial injury.
No takes yet. Share an insight, caveat, or question.
Valéro et al. (1998) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: