Little is known about respecting the recommended range of bispectral index (BIS) in practice.
What is the frequency of out-of-range bispectral index during total intravenous anesthesia, and do patient characteristics impact this frequency?
What is the frequency of out-of-range bispectral index during total intravenous anesthesia, and do patient characteristics impact this frequency?
Answers are grounded in this paper and cite their sources.
During total intravenous anesthesia, patients frequently experience bispectral index values below the recommended range, with female sex and lower BMI being significant risk factors.
Little is known about respecting the recommended range of bispectral index (BIS) in practice. This exploratory retrospective analysis of 138 robotic surgical patients having received total intravenous anesthesia shows that BIS was between 40 and 60 during 61.3% ± 25.2% (mean ± standard deviation [SD]) of maintenance, >60 during 3.1% ± 5.5%, and <40 during 35.7% ± 26.9%. Burst suppression was present during 17.8% ± 22.2%. Female sex is associated with increased periods of BIS <40 (P = .002) as is body mass index (BMI) <26 (P = .012). Increased age is associated with increase in burst suppression (P = .005). A larger study is required to confirm the role of patients' factors on the number of periods of low BIS.
No takes yet. Share an insight, caveat, or question.
Gross et al. (2019) studied this question.