Why the study?
Contact feedback was previously unavailable for remote magnetic navigation-guided catheter ablation, prompting the evaluation of the novel e-Contact Module on acute and long-term outcomes in ischemic VT ablation.
Does contact feedback using the e-Contact Module improve 1-year VT-free survival in patients undergoing remote magnetic navigation-guided ischemic ventricular tachycardia ablation?
Does contact feedback using the e-Contact Module improve 1-year VT-free survival in patients undergoing remote magnetic navigation-guided ischemic ventricular tachycardia ablation?
The implementation of contact feedback via the e-Contact Module during remote magnetic navigation-guided ablation for ischemic VT significantly reduces fluoroscopy exposure and improves 1-year VT-free survival.
Answers are grounded in this paper and cite their sources.
May support ECM use in magnetic VT ablation; leaves open randomized confirmation of benefit.
INTRODUCTION: Remote magnetic navigation (RMN)-guided catheter ablation (CA) is a feasible treatment option for patients presenting with ischemic ventricular tachycardia (VT). Catheter-tissue contact feedback, enhances lesion formation and may consequently improve CA outcomes. Until recently, contact feedback was unavailable for RMN-guided CA. The novel e-Contact Module (ECM) was developed to continuously monitor and ensure catheter-tissue contact during RMN-guided CA. OBJECTIVE: The present study aims to evaluate the effect of ECM implementation on acute and long-term outcomes in RMN-guided ischemic VT ablation. METHOD: This retrospective, two-center study included consecutive ischemic VT patients undergoing RMN-guided CA from 2010 to 2017. Baseline clinical data, procedural data, including radiation times, and acute success rates were compared between CA procedures performed with ECM (ECM+) and without ECM (ECM-). One-year VT-free survival was analyzed using Cox-proportional hazards models, adjusting for potential confounders: age, left ventricular function, VT inducibility at baseline and substrate based ablation strategy. RESULTS: The current study included 145 patients (ECM+ N = 25, ECM- N = 120). Significantly lower fluoroscopy times were observed in the ECM+ group (9.5 (IQR 5.3-13.5) versus 12.5 min (IQR 8.0-18.0), P = 0.025). Non-inducibility of the clinical VT at the end of procedure was observed in 92% ECM+ versus 72% ECM- patients (P = 0.19). ECM guidance was associated with significantly lower VT-recurrence rates during 1-year follow-up (16% ECM+ versus 40% ECM-; multivariable HR 0.29, 95%-CI 0.10-0.69, P = 0.021, reference group: ECM-). CONCLUSION: Contact feedback by the ECM further decreases fluoroscopy exposure and improves VT-free survival in RMN-guided ischemic VT ablation.
No takes yet. Share an insight, caveat, or question.
Noten et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: