Why the study?
Does SAFE-T mapping accurately identify the origin of idiopathic RVOT-VT during sinus rhythm?
Does SAFE-T mapping accurately identify the origin of idiopathic RVOT-VT during sinus rhythm?
SAFE-T mapping is a feasible and accurate online tool for quantifying diseased ventricular substrate and identifying optimal ablation targets for idiopathic RVOT-VT during sinus rhythm.
Answers are grounded in this paper and cite their sources.
May aid sinus-rhythm localization of idiopathic RVOT-VT origins; hypothesis-generating and requires prospective validation before adoption.
INTRODUCTION: The signal characteristics of intracardiac bipolar electrograms at the origin of idiopathic RVOT-VT during sinus rhythm remain unclear. OBJECTIVE: The study sought to develop a novel real-time/online technique, simultaneous amplitude frequency electrogram transformation (SAFE-T), to quantify and localize the diseased ventricular substrate in idiopathic RVOT-VT. METHODS: We retrospectively investigated the intracardiac bipolar recordings in 70 consecutive patients (26% male, mean age 42±12 years) who underwent successful radiofrequency catheter ablation of idiopathic RVOT-VT. We quantified the extent of the frequency fraction of ventricular potentials during sinus rhythm or ventricular pacing using a novel formula, the product of instantaneous amplitude and frequency, and showed that in a 3D geometry as an online SAFE-T map. RESULTS: The characteristics of the HHT spectra of electrograms derived from VT origins demonstrated high frequency components (>70 Hz), which were independent of the rhythm. The density of the abnormal potentials at the VT origins were higher (VT origins, 7.5±2.3 sites/cm2 vs. surrounding myocardium, 1.5±1.3 sites/cm2, p<0.001), and were significantly decreased after ablation (0.7±0.6 sites/cm2, p<0.001). A small region of abnormal potentials were observed in the VT origins (mean area of 1.5±0.8 cm2). The SAFE-T maps predicted the VT origins with 92% sensitivity, 78% specificity with optimal cut-off value of >3.0 Hz·mV. CONCLUSION: The online SAFE-T map was feasible for quantifying the diseased ventricular substrate, irrespective of the rhythm of activation, and can be used to identify the optimal ablation targets for idiopathic RVOT-VT. We found a limited region of abnormal potentials where the RVOT-VT origins were successfully ablated.
No takes yet. Share an insight, caveat, or question.
Te et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: