Multilevel converter topologies are widely used in applications of wide-power range. The T-type topology, which is one of many three-level topologies, has an advantage in terms of efficiency compared to the neutral-point-clamped (NPC) type. In applications using the T-type topology, interest in reliability has been increased recently. Therefore, the open-switch fault detection method and tolerance control for T-type rectifiers, which are different from those of T-type inverters, are necessary to improve the reliability of applications. When the open-switch fault of switches connected to a neutral point occurs, an NPC-type rectifier cannot restore distorted input currents; however, a T-type rectifier is able to eliminate input current distortion completely. In this paper, an open-switch fault detection method is proposed and can find a position of the open-switch fault. Moreover, two tolerance controls based on space vector modulation are proposed and their characteristics are analyzed. The effectiveness and performance of the proposed open-switch fault detection method and two tolerance controls are verified by simulations and experiments.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: