Key result
The AICA-WT technique exhibited the best artifact removal performance compared to other methods and identified a deceleration of EEG dominant frequencies in VaD and MCI patients.
Why the study?
Does the AICA-WT technique improve artifact removal in EEG signals of patients with post-stroke dementia compared to other AICA and WT methods?
Cross-Sectional (n=35)
Does the AICA-WT technique improve artifact removal in EEG signals of patients with post-stroke dementia compared to other AICA and WT methods?
Answers are grounded in this paper and cite their sources.
The proposed AICA-WT technique effectively removes artifacts from EEG signals, enabling better spectral analysis of background activities in patients with vascular dementia and stroke-related MCI.
Characterizing dementia is a global challenge in supporting personalized health care. The electroencephalogram (EEG) is a promising tool to support the diagnosis and evaluation of abnormalities in the human brain. The EEG sensors record the brain activity directly with excellent time resolution. In this study, EEG sensor with 19 electrodes were used to test the background activities of the brains of five vascular dementia (VaD), 15 stroke-related patients with mild cognitive impairment (MCI), and 15 healthy subjects during a working memory (WM) task. The objective of this study is twofold. First, it aims to enhance the recorded EEG signals using a novel technique that combines automatic independent component analysis (AICA) and wavelet transform (WT), that is, the AICA-WT technique; second, it aims to extract and investigate the spectral features that characterize the post-stroke dementia patients compared to the control subjects. The proposed AICA-WT technique is a four-stage approach. In the first stage, the independent components (ICs) were estimated. In the second stage, three-step artifact identification metrics were applied to detect the artifactual components. The components identified as artifacts were marked as critical and denoised through DWT in the third stage. In the fourth stage, the corrected ICs were reconstructed to obtain artifact-free EEG signals. The performance of the proposed AICA-WT technique was compared with those of two other techniques based on AICA and WT denoising methods using cross-correlation X C o r r and peak signal to noise ratio ( P S N R ) (ANOVA, p ˂ 0.05). The AICA-WT technique exhibited the best artifact removal performance. The assumption that there would be a deceleration of EEG dominant frequencies in VaD and MCI patients compared with control subjects was assessed with AICA-WT (ANOVA, p ˂ 0.05). Therefore, this study may provide information on post-stroke dementia particularly VaD and stroke-related MCI patients through spectral analysis of EEG background activities that can help to provide useful diagnostic indexes by using EEG signal processing.
No takes yet. Share an insight, caveat, or question.
Al-Qazzaz et al. (2017) conducted a cross-sectional in Vascular dementia and stroke-related mild cognitive impairment (n=35). AICA-WT technique vs. Other AICA and WT denoising methods was evaluated on Artifact removal performance (cross-correlation and peak signal to noise ratio) (p=<0.05). The AICA-WT technique exhibited the best artifact removal performance compared to other methods and identified a deceleration of EEG dominant frequencies in VaD and MCI patients.