Key result
In a porcine model of continuous pulmonary flow, pulmonary pressure could not be predicted using Linehan's equation, though distensibility was inversely correlated with resistance.
Why the study?
Resistance varies nonlinearly with pressure and flow in the pulmonary circulation, prompting validation of Linehan et al.'s distensibility-incorporating equation in an in vivo porcine model.
Answers are grounded in this paper and cite their sources.
May invalidate Linehan's equation in continuous pulmonary flow; leaves open human translation of distensibility-resistance links.
In the pulmonary circulation, resistive and compliant properties overlap in the same vessels. Resistance varies nonlinearly with pressure and flow; this relationship is driven by the elastic properties of the vessels. Linehan et al. correlated the mean pulmonary arterial pressure and mean flow with resistance using an original equation incorporating the distensibility of the pulmonary arteries. The goal of this study was to validate this equation in an in vivo porcine model. In vivo measurements were acquired in 6 pigs. The distensibility coefficient (DC) was measured by placing piezo-electric crystals around the pulmonary artery (PA). In addition to experiments under pulsatile conditions, a right ventricular (RV) bypass system was used to induce a continuous pulmonary flow state. The Linehan et al. equation was then used to predict the pressure from the flow under continuous flow conditions. The diameter-derived DC was 2.4%/mmHg (+/-0.4%), whereas the surface area-based DC was 4.1 %/mmHg (+/-0.1%). An increase in continuous flow was associated with a constant decrease in resistance, which correlated with the diameter-based DC (r=-0.8407, p=0.044) and the surface area-based DC (r=-0.8986, p=0.028). In contrast to the Linehan et al. equation, our results showed constant or even decreasing pressure as flow increased. Using a model of continuous pulmonary flow induced by an RV assist system, pulmonary pressure could not be predicted based on the flow using the Linehan et al. equation. Measurements of distensibility based on the diameter of the PA were inversely correlated with the resistance.
No takes yet. Share an insight, caveat, or question.
Eynden et al. (2019) studied Normal pulmonary circulation (experimental model) (n=6). Right ventricular continuous flow pump vs. Predicted values from Linehan's equation was evaluated on Correlation between resistance at highest common flow and diameter-based distensibility coefficient (DCα) (r= -0.8407, p=0.044). In a porcine model of continuous pulmonary flow, pulmonary pressure could not be predicted using Linehan's equation, though distensibility was inversely correlated with resistance.
Synapse has enriched 10 related papers. Consider them for comparative context: