Key result
A 2D U-net segmentation model using ReLU activation achieved 99% accuracy for cardiac MRI frames, outperforming the MISH activation function.
Why the study?
Heart disease is a major global cause of morbidity and mortality, and cardiac structures such as the left ventricle differ complexly across end-diastole and end-systole phases on cine cardiac MRI.
Does the use of ReLU activation improve segmentation accuracy and mean IoU compared to MISH in a 2D U-net model for cine cardiac MRI?
Does the use of ReLU activation improve segmentation accuracy and mean IoU compared to MISH in a 2D U-net model for cine cardiac MRI?
In a 2D U-net model for cardiac MRI segmentation, ReLU activation outperformed MISH activation in accuracy, loss, and mean IoU for end-diastole frames.
Answers are grounded in this paper and cite their sources.
ReLU may aid cardiac MRI segmentation pipelines; leaves open clinical translation and external validation.
Heart disease, especially Coronary Heart Disease (CHD) is a major cause of morbidity and mortality in all corners of the world. In Indonesia in particular, this disease is the highest burden of government financing. The heart as an important organ in humans has a complexity in its structure, for example, the appearance of the left ventricle will look different in two phases of heart rate, End-Diastole (ED) and End-Systole (ES). In this study, the discussion focuses on the multi-structures segmentation of the 2017 ACDC public cine cardiac MRI dataset consisting of training data from 100 patients and test data from 50 patients. Annotations made by experts are included in the training data. The Deep Learning segmentation model is built based on the 2D U-net architecture by taking into account the selection of activation functions, especially in ED and ES frames. The experimental results show that the use of ReLU activation gives better results than MISH with an accuracy of 99% for both ED and ES frames, 2% higher than ED with MISH. Furthermore, although in general the loss from multiclass segmentation is said to be good with a value range of 10 – 2, the loss due to ReLU shows better results, which is 0.02 lower than 0.04 MISH. Furthermore, the mean IoU value, quantifying the similarity between the original image and the predicted image, was found to be 0.815 for ED with ReLU and this value was 0.2 higher than ED with MISH. As for ES, the mean IoU between ReLU and MISH is not much different, which is around 0.7. As sustainability, in the next research, it is necessary to search for known method for classifying by right each part of the multi-structures heart, particularly the myocardium, in an effort to help diagnose CHD cases.
No takes yet. Share an insight, caveat, or question.
Riandini et al. (2022) studied Heart disease (n=150). 2D U-net with ReLU activation vs. 2D U-net with MISH activation was evaluated on Segmentation accuracy for End-Diastole (ED) and End-Systole (ES) frames. A 2D U-net segmentation model using ReLU activation achieved 99% accuracy for cardiac MRI frames, outperforming the MISH activation function.
Synapse has enriched 10 related papers. Consider them for comparative context: