Key result
Spontaneously terminating AF is linked to a ~88% lower spatial autocorrelation dimension than sustained AF.
Why the study?
The factors governing AF and VF termination are poorly understood, and whether the ratio of system size to spatial correlation length predicts termination had not been systematically studied in human AF and VF.
Does spatial autocorrelation dimension predict the temporal persistence of human atrial and ventricular fibrillation?
Observational (n=76)
Yes
Does spatial autocorrelation dimension predict the temporal persistence of human atrial and ventricular fibrillation?
Spatial autocorrelation dimension (Di) is a novel metric that predicts the temporal persistence and likelihood of spontaneous termination in human AF and VF.
Lower spatial autocorrelation dimension was associated with spontaneous termination in AF/VF; hypothesis-generating and requires prospective validation before clinical adoption.
Background: Despite being central to atrial fibrillation (AF) and ventricular fibrillation (VF) mechanisms and therapy, the factors governing AF and VF termination are poorly understood. It has been noted that ratio of system size ( L ) and the two-point spatial correlation length (ξ 2 ) are associated with time until termination in transient spatiotemporally chaotic systems, but the relationship between these characteristics and termination has not been systematically studied in human AF and VF. Objective: We aimed assess whether the time to cardiac fibrillation termination can be predicted using a novel estimator, the spatial autocorrelation dimension ( D i ), defined as the ratio of L and ξ 2 , in human AF and VF. Methods: D i was computed and compared in a multi-centre, multi-system study with data for sustained versus spontaneously terminating human AF/VF. VF data was collected during coronary-bypass surgery; and AF data during clinically indicated AF ablation. We analyzed: i) VF mapped using a 256-electrode epicardial sock (n=12pts); ii) AF mapped using a 64-electrode constellation basket-catheter (n=15pts); iii) AF mapped using a 16-electrode HD-grid catheter (n=42pts). To investigate temporal fibrillation persistence, the response of AF-episodes to flecainide (n=7pts) was also studied. Results: Spontaneously terminating fibrillation demonstrated a lower D i (P<0.001 all systems). Lower D i was also seen in paroxysmal compared to persistent AF (P=0.002). Post-flecainide, D i decreased over time (P<0.001). Lower D i was also associated with longer-lasting episodes of AF/VF (R 2 >0.90, P<0.05 in all cases). Using k-means clustering, two distinct clusters and their centroids were identified i) a cluster of spontaneously terminating episodes, and ii) a cluster of sustained epochs. Conclusion: D i predicts the temporal persistence of cardiac fibrillation. This finding provides potentially important insights into a possible common pathway to termination and therapeutic approaches.
No takes yet. Share an insight, caveat, or question.
Dharmaprani et al. (2023) conducted an observational in Atrial and ventricular fibrillation (n=76). Spontaneously terminating fibrillation vs. Sustained fibrillation was evaluated on Spatial autocorrelation dimension (Di) in HD-grid mapped human AF (p=0.001). Spontaneously terminating fibrillation demonstrated a lower spatial autocorrelation dimension compared to sustained fibrillation across all mapping systems.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: