Key result
Hemochron Signature point-of-care testing using PT/INR and ACT+ cards detected safe concentrations of rivaroxaban and dabigatran with >95% specificity, but did not correlate with apixaban.
Why the study?
Does Hemochron Signature point-of-care testing accurately rule out relevant concentrations of apixaban, rivaroxaban, and dabigatran in patients treated with direct oral anticoagulants?
Observational (n=68)
Blinded end-point assessment
No
Does Hemochron Signature point-of-care testing accurately rule out relevant concentrations of apixaban, rivaroxaban, and dabigatran in patients treated with direct oral anticoagulants?
Hemochron Signature point-of-care testing using PT/INR and ACT+ test cards can rapidly and reliably rule out relevant concentrations of rivaroxaban and dabigatran to guide emergency treatment, but is not effective for apixaban.
Answers are grounded in this paper and cite their sources.
May support emergency decisions for rivaroxaban and dabigatran but not apixaban; leaves open prospective validation before practice change.
BACKGROUND: Point-of-care testing (POCT) of coagulation has been proven to be of great value in accelerating emergency treatment. Specific POCT for direct oral anticoagulants (DOAC) is not available, but the effects of DOAC on established POCT have been described. We aimed to determine the diagnostic accuracy of Hemochron® Signature coagulation POCT to qualitatively rule out relevant concentrations of apixaban, rivaroxaban, and dabigatran in real-life patients. METHODS: We enrolled 68 patients receiving apixaban, rivaroxaban, or dabigatran and obtained blood samples at six pre-specified time points. Coagulation testing was performed using prothrombin time/international normalized ratio (PT/INR), activated partial thromboplastin time (aPTT), and activated clotting time (ACT+ and ACT-low range) POCT cards. For comparison, laboratory-based assays of diluted thrombin time (Hemoclot) and anti-Xa activity were conducted. DOAC concentrations were determined by liquid chromatography-tandem mass spectrometry. RESULTS: Four hundred and three samples were collected. POCT results of PT/INR and ACT+ correlated with both rivaroxaban and dabigatran concentrations. Insufficient correlation was found for apixaban. Rivaroxaban concentrations at <30 and <100 ng/mL were detected with >95% specificity at PT/INR POCT ≤1.0 and ≤1.1 and ACT+ POCT ≤120 and ≤130 s. Dabigatran concentrations at <30 and <50 ng/mL were detected with >95% specificity at PT/INR POCT ≤1.1 and ≤1.2 and ACT+ POCT ≤100 s. CONCLUSIONS: Hemochron® Signature POCT can be a fast and reliable alternative for guiding emergency treatment during rivaroxaban and dabigatran therapy. It allows the rapid identification of a relevant fraction of patients that can be treated immediately without the need to await the results of much slower laboratory-based coagulation tests. TRIAL REGISTRATION: Unique identifier, NCT02371070 . Retrospectively registered on 18 February 2015.
No takes yet. Share an insight, caveat, or question.
Ebner et al. (2017) conducted an observational in Patients treated with direct oral anticoagulants (apixaban, rivaroxaban, or dabigatran) (n=68). Hemochron Signature coagulation POCT vs. Laboratory-based UPLC-MS and DOAC-specific coagulation assays was evaluated on Specificity of ACT+ POCT (≤120 s) for detecting rivaroxaban concentrations <30 ng/mL (96% specificity, 95% CI 87-99, p=<0.001). Hemochron Signature point-of-care testing using PT/INR and ACT+ cards detected safe concentrations of rivaroxaban and dabigatran with >95% specificity, but did not correlate with apixaban.
Synapse has enriched 10 related papers. Consider them for comparative context: