Key result
Passive leg lift LA strain-volume slope detects elevated PAWP with an AUC of ~0.89.
Why the study?
Assessing LV filling pressure in HF is challenging because resting pressures may be normal while elevated during exercise, and passive leg lift may unmask elevated pressures.
Does the left atrial strain-volume relationship during passive leg lift improve the identification of elevated left ventricular filling pressure in patients with suspected heart failure compared to conventional echocardiographic measures?
Observational (n=55)
No
Does the left atrial strain-volume relationship during passive leg lift improve the identification of elevated left ventricular filling pressure in patients with suspected heart failure compared to conventional echocardiographic measures?
Effect estimate: AUC 0.89 (95% CI 0.76-1.00)
The left atrial strain-volume relationship during passive leg lift provides incremental diagnostic value over conventional echocardiographic measures for identifying elevated left ventricular filling pressure in heart failure.
May aid noninvasive PAWP estimation in heart failure; extends conventional echo but leaves open prospective validation.
Background: The assessment of left ventricular (LV) filling pressure in heart failure (HF) poses a diagnostic challenge, as HF patients may have normal LV filling pressures at rest but often display elevated LV filling pressures during exercise. Rapid preload increase during passive leg lift (PLL) may unmask HF in such challenging scenarios. We explored the dynamic interplay between simultaneous left atrial (LA) function and volume using LA strain/volume loops during rest and PLL and compared its diagnostic performance with conventional echocardiographic surrogates to detect elevated LV filling pressure. Methods: We retrospectively reviewed 35 patients with clinical HF who underwent simultaneous echocardiography and right heart catheterization before and immediately after PLL. Patients with atrial fibrillation (n = 4) were excluded. Twenty age-matched, healthy controls were added as controls. LA reservoir strain (LASr) was analyzed using speckle-tracking echocardiography. LA strain–volume loops were generated, including the best-fit linear regression line employing simultaneous LASr and LA volume. Results: LA strain–volume slope was lower for HF patients when compared with controls (0.71 vs. 1.22%/mL, p < 0.001). During PLL, the LA strain–volume slope displayed a moderately strong negative correlation with invasive pulmonary arterial wedge pressure (PAWP) (r = −0.71, p < 0.001). At a 0.74%/mL cut-off, the LA strain–volume slope displayed 88% sensitivity and 86% specificity to identify elevated PAWP (AUC 0.89 [0.76–1.00]). In comparison, LASr demonstrated strong but numerically lower diagnostic performance (AUC 0.82 [0.67–0.98]), and mitral E/e’ showed poor performance (AUC 0.57 [0.32–0.82]). Conclusions: In this proof-of-concept study, LA strain–volume characteristics provide incremental diagnostic value over conventional echocardiographic measures in the identification of elevated LV filling pressure.
No takes yet. Share an insight, caveat, or question.
Venkateshvaran et al. (2024) conducted an observational in Heart failure with suspected elevated left ventricular filling pressure (n=55). Left atrial strain-volume slope during passive leg lift vs. Conventional echocardiographic measures (LA reservoir strain, mitral E/e') was evaluated on Identification of elevated pulmonary arterial wedge pressure (PAWP) (AUC 0.89, 95% CI 0.76-1.00). The left atrial strain-volume slope during passive leg lift identified elevated pulmonary arterial wedge pressure with an AUC of 0.89, outperforming conventional echocardiographic measures.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: