Key result
During ischemia, blood-perfused rabbit hearts exhibited a larger mean calcium transient alternans ratio compared to saline-perfused hearts.
Ischemia induces calcium transient alternans more frequently and severely in blood-perfused compared to saline-perfused rabbit hearts, which may relate to the development of ischemic arrhythmias.
Answers are grounded in this paper and cite their sources.
Should not yet change clinical ischemia management; hypothesis-generating for blood factors in calcium alternans.
Ischemia produces striking electrophysiological abnormalities in blood-perfused hearts that may be caused, in part, by effects of ischemia on intracellular calcium. To test this hypothesis, intracellular Ca2+ concentration ([Ca2+]i) transients were recorded from the epicardial surface of blood- and saline-perfused rabbit hearts using the long-wavelength indicator Fura Red. Calcium transients were much larger than the movement artifact, representing up to 29% of the total signal. Switching the perfusate from saline to blood did not affect the time course of the transients or the apparent level of [Ca2+]i. Compartmentation of Fura Red fluorescence was estimated by exposure to Mn2+. The results were cytosol 60 +/- 3%, organelles 12 +/- 2%, and autofluorescence plus partly deesterified Fura Red 29 +/- 4%. [Ca2+]i transients were calibrated in situ by perfusion of the extracellular space with high-Ca2+ and Ca(2+)-free EGTA solutions. Peak systolic [Ca2+]i was 663 +/- 74 nM, and end-diastolic [Ca2+]i was 279 +/- 59 nm. Ischemia was produced by interruption of aortic perfusion for 2.5 min during pacing (150 beats/min). Ischemia produced broadening of the [Ca2+]i transient, along with beat-to-beat alternations in the peak systolic and end-diastolic level of [Ca2+]i (calcium transient alternans). [Ca2+]i transient alternans occurred in 82% of blood-perfused hearts vs. 43% of saline-perfused hearts. The discrepancy between large and small transients (mean alternans ratio) was larger in the blood-perfused hearts (0.23 +/- 0.04 vs. 0.07 +/- 0.03, P = 0.005). These observations are important because of the apparent relationship of [Ca2+]i transient alternans to electrical alternans and arrhythmias during ischemia.
No takes yet. Share an insight, caveat, or question.
Wu et al. (1997) studied Ischemia. Blood perfusion vs. Saline perfusion was evaluated on Mean alternans ratio during ischemia (p=0.005). During ischemia, blood-perfused rabbit hearts exhibited a larger mean calcium transient alternans ratio compared to saline-perfused hearts.
Synapse has enriched 10 related papers. Consider them for comparative context: