Key result
Laboratory tonometric blood pressure matches ambulatory monitoring in 76% of hypertension classifications.
Why the study?
To compare blood pressure in tonometric radial artery recordings during passive head-up tilt with ambulatory recordings and evaluate potential laboratory cutoff values for hypertension.
Does tonometric laboratory blood pressure measurement accurately classify hypertension compared to ambulatory daytime blood pressure monitoring in adults?
Cross-Sectional (n=410)
No
Does tonometric laboratory blood pressure measurement accurately classify hypertension compared to ambulatory daytime blood pressure monitoring in adults?
Laboratory tonometric BP measurements with a cutoff of 136/82 mmHg provide reasonable concordance with ambulatory BP monitoring for hypertension classification.
Answers are grounded in this paper and cite their sources.
May support laboratory tonometric BP as alternative to ambulatory monitoring; leaves open prospective validation before clinical use.
OBJECTIVE: To compare blood pressure (BP) in tonometric radial artery recordings during passive head-up tilt with ambulatory recordings and evaluate possible laboratory cutoff values for hypertension. METHODS: Laboratory BP and ambulatory BP were recorded in normotensive (n = 69), unmedicated hypertensive (n = 190), and medicated hypertensive (n = 151) subjects. RESULTS: Mean age was 50.2 years, BMI 27.7 kg/m 2 , ambulatory daytime BP 139/87 mmHg, and 276 were male (65%). As supine-to-upright changes in SBP ranged from -52 to +30 mmHg, and in DBP from -21 to +32 mmHg, the mean values of BP supine and upright measurements were compared with ambulatory BP. The mean(supine+upright) systolic laboratory BP was corresponding to ambulatory level (difference +1 mmHg), while mean(supine+upright) DBP was 4 mmHg lower ( P < 0.05) than ambulatory value. Correlograms indicated that laboratory 136/82 mmHg corresponded to ambulatory 135/85 mmHg. When compared with ambulatory 135/85 mmHg, the sensitivity and specificity of laboratory 136/82 mmHg to define hypertension were 71.5% and 77.3% for SBP, and 71.7% and 72.8%, for DBP, respectively. The laboratory cutoff 136/82 mmHg classified 311/410 subjects similarly to ambulatory BP as normotensive or hypertensive, 68 were hypertensive only in ambulatory, while 31 were hypertensive only in laboratory measurements. CONCLUSION: BP responses to upright posture were variable. When compared with ambulatory BP, mean(supine+upright) laboratory cutoff 136/82 mmHg classified 76% of subjects similarly as normotensive or hypertensive. In the remaining 24% the discordant results may be attributed to white-coat or masked hypertension, or higher physical activity during out-of-office recordings.
No takes yet. Share an insight, caveat, or question.
Värri et al. (2023) conducted a cross-sectional in Hypertension (n=410). Tonometric laboratory blood pressure measurement vs. Ambulatory daytime blood pressure monitoring was evaluated on Concordance of hypertension classification using laboratory cutoff 136/82 mmHg versus ambulatory cutoff 135/85 mmHg. Mean supine and upright laboratory tonometric blood pressure cutoff of 136/82 mmHg classified 76% of subjects similarly to ambulatory daytime blood pressure as normotensive or hypertensive.
Synapse has enriched 10 related papers. Consider them for comparative context: