This paper shows that there is very little effect of the silicon content on the hysteresis component of the magnetic losses when two steels with 2.45% and 3.3% silicon were compared. Two non-oriented steels with 2.45 wt% and 3.3 wt% Si have been investigated. The Hysteresis component was measured by two techniques, in an Epstein frame: by a quasi-static test at 5 MHz and by extrapolating the total loss from frequencies above 50 Hz. The results showed that the quasi-static hysteresis loss (5 MHz) is not affected by increased Si content. The method of measurement by extrapolating-from frequencies above 50 Hz-(W* h ) proved inaccurate, as it is influenced by the electrical resistivity of the steels.
No takes yet. Share an insight, caveat, or question.
Almeida et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: