Key result
The simultaneous acquisition rest 99mTc-tetrofosmin/stress 201Tl dual-isotope protocol demonstrated a higher diagnostic accuracy for detecting coronary ischemia compared to the rest-stress 99mTc-tetrofosmin protocol.
Why the study?
Does the simultaneous dual-isotope protocol improve diagnostic accuracy for coronary ischemia compared to the rest-stress Tc/Tc protocol in patients undergoing stress MPI?
Observational (n=147)
No
Does the simultaneous dual-isotope protocol improve diagnostic accuracy for coronary ischemia compared to the rest-stress Tc/Tc protocol in patients undergoing stress MPI?
The simultaneous dual-isotope protocol using a semiconductor camera provides higher diagnostic accuracy for detecting coronary ischemia than the standard rest-stress Tc/Tc protocol.
Answers are grounded in this paper and cite their sources.
Supports potential for dual-isotope MPI to enhance ischemia detection; hypothesis-generating and requires randomized confirmation before practice change.
BACKGROUND: Tl dual-isotope protocol (SDI protocol) with a semiconductor camera. METHODS AND RESULTS: We retrospectively studied 147 patients who underwent stress MPI using a cadmium-zinc-telluride camera and invasive coronary angiography within a 3-month interval. The Tc/Tc and SDI protocols were used in 59 and 88 patients, respectively. The sensitivity, specificity, and accuracy of the summed difference score in per-patient analysis were 56%, 85%, and 69%, respectively, for the Tc/Tc protocol and 89%, 82%, and 85%, respectively, for the SDI protocol. The area under the receiver operating characteristic curve was significantly better for the SDI than Tc/Tc protocol for the left anterior descending artery (0.836 vs. 0.674; P=0.0380), the left circumflex artery (0.754 vs. 0.599; P=0.0441), and in per-patient analysis (0.875 vs. 0.707; P=0.0135). There was no significant difference in the diagnostic accuracy of the summed stress score for any vessel or in per-patient analysis between the 2 protocols. CONCLUSIONS: The SDI protocol had a higher diagnostic accuracy for the detection of coronary ischemia than the Tc/Tc protocol.
No takes yet. Share an insight, caveat, or question.
Kawamura et al. (2018) conducted an observational in Coronary artery disease (n=147). Simultaneous acquisition rest 99mTc-tetrofosmin/stress 201Tl dual-isotope (SDI) protocol vs. Rest-stress 99mTc-tetrofosmin (Tc/Tc) protocol was evaluated on Area under the receiver operating characteristic curve (AUC) for the detection of coronary artery stenosis in per-patient analysis (p=0.0135). The simultaneous acquisition rest 99mTc-tetrofosmin/stress 201Tl dual-isotope protocol demonstrated a higher diagnostic accuracy for detecting coronary ischemia compared to the rest-stress 99mTc-tetrofosmin protocol.
Synapse has enriched 10 related papers. Consider them for comparative context: