Key result
Following TAVR, baseline markedly enlarged left atrium was significantly associated with a higher risk of new-onset atrial fibrillation (HR 4.72; 95% CI 1.11-20.13; P=0.04).
Why the study?
Does transcatheter aortic valve replacement improve left atrial volumetric function in patients with severe aortic stenosis in sinus rhythm?
Cohort (n=121)
Does transcatheter aortic valve replacement improve left atrial volumetric function in patients with severe aortic stenosis in sinus rhythm?
Hazard Ratio: 4.72 (95% CI 1.11–20.13)
p-value: p=0.04
TAVR improves left atrial reservoir and conduit function over time, and lack of negative LA remodeling post-TAVR is associated with a higher incidence of new-onset atrial fibrillation.
Enlarged baseline LA flags higher post-TAVR AF risk; leaves open whether size-guided monitoring improves outcomes.
OBJECTIVES: To investigate the effect of transcatheter aortic valve replacement on left atrial volumetric function and left atrial volume for the prediction of adverse outcomes. METHODS: This is a retrospective analysis of 121 patients in sinus rhythm who underwent TAVR for severe AS. Maximum LA volume index (LAVI max), minimum LA volume index (LAVI min), and "pre-A" volume index (LAVIpre-A, the volume before atrial contraction) were measured by biplane Simpson's method at baseline, 1 month, and 1 year. The reservoir function, conduit function, booster pump function were calculated. All patients were followed for new-onset of atrial fibrillation, hospitalization and all-cause mortality. RESULTS: The reservoir function, conduit function and booster function before TAVR were 46%, 21%, 32%, respectively. LA volumetric function assessment demonstrated that reservoir function, conduit function increased over the time (all P < 0.01). There was no difference in booster function after TAVR (P = 0.18). Baseline markedly enlarged LA was significantly increased for AF (HR: 4.72; 95% CI, 1.11-20.13, P = 0.04). In addition, There was a progressive decrease in LAVI max (P = 0.02) and RVSP (P = 0.03) over the time in non-AF group but not in AF group (P = 0.62 and P = 0.65, respectively). Although, the proportion of high left ventricular filling pressure decreased in both groups but a marked decrease was noted in non AF group in compared with AF group. CONCLUSION: Reservoir function, conduit function increased over time. Lack of negative LA remodeling post TAVR was associated with higher incidence of AF.
No takes yet. Share an insight, caveat, or question.
Truong et al. (2018) conducted a cohort in Severe aortic stenosis (n=121). Transcatheter aortic valve replacement (TAVR) vs. Baseline was evaluated on New-onset atrial fibrillation (predicted by baseline markedly enlarged LA) (HR 4.72, 95% CI 1.11-20.13, p=0.04). Following TAVR, baseline markedly enlarged left atrium was significantly associated with a higher risk of new-onset atrial fibrillation (HR 4.72; 95% CI 1.11-20.13; P=0.04).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: