Key result
Transcatheter aortic valve implantation significantly improved left atrial appendage function, increasing mean LAA filling velocity to 42.3 cm/s compared to 38.8 cm/s at baseline.
Why the study?
Does transcatheter aortic valve implantation improve left atrial appendage function in patients with severe symptomatic aortic stenosis?
Observational (n=55)
Single-blind
No
Does transcatheter aortic valve implantation improve left atrial appendage function in patients with severe symptomatic aortic stenosis?
Absolute Event Rate: 42.3% vs 38.8%
p-value: p=<0.001
Transcatheter aortic valve implantation improves left atrial appendage function in the short term, particularly in patients with reduced LVEF and marked left ventricular diastolic dysfunction.
TAVI-associated LAA gains in severe AS support further study in diastolic dysfunction; leaves open effects on stroke risk and anticoagulation.
BACKGROUND: The beneficial effects of the transcatheter aortic valve implantation (TAVI) on echocardiographic parameters including left atrial (LA) and left ventricular (LV) functions were described by previous studies. The aim of this study was to analyze the effects of TAVI on left atrial appendage (LAA) function assessed by transthoracic and transesophageal echocar-diography. METHODS: Fifty-five patients with severe symptomatic aortic stenosis were included in this prospective study. LAA early and late emptying velocities, LAA filling velocity, peak early diastolic (EM), late diastolic (AM), and systolic (SM) velocities were measured with pulsed wave Doppler and tissue Doppler imaging, and E/Em ratio was calculated before and 7.1 ± 2.8 days after TAVI. A subgroup analysis was performed in accordance with the left ventricular ejection fraction (LVEF) of the patients and the severity of their LV diastolic dysfunction. RESULTS: Although the post-procedure peaks and mean gradients of the patients decreased sig-nificantly, the LVEF increased significantly in those who had low LVEF before the procedure. The post-procedure E/Em ratio decreased significantly (p < 0.001). The post-procedural LAA mean filling velocity and EM velocity were significantly higher than the pre-procedural filling velocity (p < 0.001, p = 0.002, respectively). In the subgroup analysis, the post-procedural LAA filling velocity, early and late LAA emptying velocities, in addition to the mean velocity of the EM, AM, and SM were significantly higher than before the procedure in patients with LVEF of < 50% and E/Em ratios of > 15. CONCLUSIONS: LAA function improved soon after the TAVI procedure, especially in patients with low LVEF and marked LV diastolic dysfunction.
No takes yet. Share an insight, caveat, or question.
Aslan et al. (2015) conducted an observational in Severe symptomatic aortic stenosis (n=55). Transcatheter aortic valve implantation (TAVI) vs. Pre-procedure baseline was evaluated on Left atrial appendage (LAA) filling velocity (cm/s) (p=<0.001). Transcatheter aortic valve implantation significantly improved left atrial appendage function, increasing mean LAA filling velocity to 42.3 cm/s compared to 38.8 cm/s at baseline.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: