Key result
Trans-catheter aortic valve implantation improved LV function and preserved RV systolic function, whereas aortic valve replacement resulted in depressed TAPSE (P<0.001) and reversed septal motion (P<0.001).
Why the study?
Does TAVI improve early left and right ventricular function compared to AVR in patients with severe aortic stenosis?
Cohort (n=80)
Does TAVI improve early left and right ventricular function compared to AVR in patients with severe aortic stenosis?
p-value: p=<0.001
TAVI provides early improvement in LV systolic and diastolic function while preserving RV systolic function, unlike surgical AVR which depresses RV function early post-operatively.
TAVI may better preserve early RV function than AVR in severe AS; leaves open clinical impact pending randomized confirmation.
This study aimed to assess the early effect of trans-catheter aortic valve implantation (TAVI) on right (RV) and left ventricular (LV) function in severe aortic stenosis (AS) patients. Twenty AS patients (age 79±6 years) were examined before, one week and six weeks after TAVI using Doppler echocardiography. LV ejection fraction (EF), long-axis [mitral annular plane systolic excursion (MAPSE)] and RV long-axis [tricuspid annular plane systolic excursion (TAPSE)] function, septal radial motion were studied. Results were compared with 30 AS patients before and one week after aortic valve replacement (AVR) as well as 30 normals (reference group). Before TAVI, LVEF was reduced and E/A was higher than the reference and AVR groups (P<0.05 for all). MAPSE, TAPSE and septal motion were equally reduced in TAVI and AVR patients (P<0.05 for all). One week after the TAVI, EF increased in patients with values <50% before the procedure. In contrast, AVR resulted in reversed septal motion (P<0.001) and depressed TAPSE (P<0.001). The extent of reversed septal motion correlated with that of TAPSE in the patients group as a whole after procedures (r=0.78, P<0.001). Six weeks after TAVI, RV function remained unchanged, but LVEF increased and E/A decreased (P<0.05 for both). Thus, TAVI procedure results in significant early improvement of LV systolic and diastolic function particularly in patients with reduced EF and preserves RV systolic function.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2010) conducted a cohort in Severe aortic stenosis (n=80). Trans-catheter aortic valve implantation (TAVI) vs. Aortic valve replacement (AVR) and healthy controls was evaluated on Right and left ventricular function (LVEF, MAPSE, TAPSE, septal radial motion) (p=<0.001). Trans-catheter aortic valve implantation improved LV function and preserved RV systolic function, whereas aortic valve replacement resulted in depressed TAPSE (P<0.001) and reversed septal motion (P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: