November 21, 2024ACS Sensors18 citationsOpen Access

Effects of Physiological-Scale Variation in Cations, pH, and Temperature on the Calibration of Electrochemical Aptamer-Based Sensors

LFLisa FetterMMMatthew H. McDonoughTKTod E. Kippin

Key Points

Key points are not available for this paper at this time.

Abstract

Electrochemical aptamer-based (EAB) sensors are the first technology supporting high-frequency, real-time, in vivo molecular measurements that is independent of the chemical reactivity of its targets, rendering it easily generalizable. As is true for all biosensors, however, EAB sensor performance is affected by the measurement environment, potentially reducing accuracy when this environment deviates from the conditions under which the sensor was calibrated. Here, we address this question by measuring the extent to which physiological-scale environmental fluctuations reduce the accuracy of a representative set of EAB sensors and explore the means of correcting these effects. To do so, we first calibrated sensors against vancomycin, phenylalanine, and tryptophan under conditions that match the average ionic strength, cation composition, pH, and temperature of healthy human plasma. We then assessed their accuracy in samples for which the ionic composition, pH, and temperature were at the lower and upper ends of their physiological ranges. Doing so, we find that physiologically relevant fluctuations in ionic strength, cation composition, and pH do not significantly harm EAB sensor accuracy. Specifically, all 3 of our test-bed sensors achieve clinically significant mean relative accuracy (i.e., better than 20%) over the clinically or physiologically relevant concentration ranges of their target molecules. In contrast, physiologically plausible variations away from the temperature used for calibration induce more substantial errors. With knowledge of the temperature in hand, however, these errors are easily ameliorated. It thus appears that physiologically induced changes in the sensing environment are likely not a major impediment to clinical application of this in vivo molecular monitoring technology.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fetter et al. (2024) studied this question.

synapsesocial.com/papers/6a20376960a84f4b7dd8e1f9https://doi.org/10.1021/acssensors.4c02274
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Real-Time, Aptamer-Based Tracking of Circulating Therapeutic Agents in Living Animals2013 · 427 citations
  2. 2Stability of cerebrospinal fluid pH in chronic acid-base disturbances in blood1965 · 156 citations
  3. 3High-Throughput Strategy for Enhancing Aptamer Performance across Different Environmental Conditions2023 · 17 citations
  4. 4Calcium and Bone Metabolism Indices2017 · 176 citations
  5. 5Low Temperature Greatly Enhancing Responses of Aptamer Electrochemical Sensor for Aflatoxin B1 Using Aptamer with Short Stem2020 · 96 citations