Why the study?
Are intima-media thickness of carotid and brachial arteries and prothrombin fragment 1 + 2 associated with left ventricular diastolic dysfunction in patients with previous myocardial infarction?
Are intima-media thickness of carotid and brachial arteries and prothrombin fragment 1 + 2 associated with left ventricular diastolic dysfunction in patients with previous myocardial infarction?
In patients with previous myocardial infarction, left ventricular diastolic dysfunction is independently associated with thrombin generation (prothrombin fragment 1 + 2) and atherosclerosis (intima-media thickness).
Answers are grounded in this paper and cite their sources.
Thrombin generation may link to post-MI diastolic dysfunction; cross-sectional data leave causality and interventions open.
AIMS: To investigate the association between intima-media thickness of brachial and common carotid arteries and factors of the coagulation- and fibrinolysis-system with left ventricular diastolic dysfunction in patients with a previous myocardial infarction. PATIENTS AND METHODS: One hundred and twenty three patients, men (76%) and women (24%) aged between 32 and 81 years with a history of previous acute myocardial infarction were included. B-mode ultrasound of common carotid and brachial arteries and echocardiography with tissue Doppler imaging (TDI) were evaluated. Factors of the coagulation- and fibrinolysis-system were also measured. RESULTS: In patients with previous myocardial infarction, late diastolic filling time was significantly and positively associated with log Prothrombin fragment 1 + 2 (P < 0.001) and with calculated intima-media area (cIMa) of the both common carotid and brachial arteries (P < 0.05). Mitral early-to-late flow velocity ratio (E/A) was significantly and negatively associated with log Prothrombin fragment 1 + 2 (P < 0.001), total cholesterol and cIMa of the both common carotid and brachial arteries (P < 0.05). Moreover both late diastolic filling time and mitral E/A correlated significantly with age and systolic blood pressure. In stepwise multiple regression analysis, log Prothrombin fragment 1 + 2 remained the only variable with independent significant correlation to late diastolic filling time and mitral E/A. CONCLUSIONS: In a population sample of patients with myocardial infarction, late diastolic filling time and mitral E/A were associated with cIMa of common carotid and brachial arteries, systolic blood pressure, and prothrombin fragment 1 + 2, suggesting a relationship between diastolic dysfunction, thrombin generation and atherosclerosis.
No takes yet. Share an insight, caveat, or question.
Henareh et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: