Answers are grounded in this paper and cite their sources.
Demonstrates improved phase and amplitude calibration in radiometers, highlighting a novel strategy for accuracy.
The calibration strategy for synthetic aperture interferometric radiometers based on noise injection has been successfully demonstrated in the Microwave Imaging Radiometer with Aperture Synthesis (MIRAS) instrument onboard the Soil Moisture and Ocean Salinity (SMOS) mission of the European Space Agency (ESA). With the emerging demands of increasing both array size and frequency bands, the internal calibration hardware becomes more difficult to implement. Although several external calibration methods have been proposed, the so-called phase ambiguity problem was not carefully considered. In this article, a novel calibration strategy for both phase and amplitude calibrations based on redundant space calibration is proposed, which utilizes the unique structure of equispaced circular array and rotational sampling strategy. The original irregular phase ambiguity degenerates to the fixed <tex-math notation="LaTeX">π </tex-math> -ambiguity, where only two possible solutions to phases are introduced. Both phase and amplitude of visibility can be simultaneously calibrated by the proposed strategy, and no cooperative calibration target is needed.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2021) studied this question.