Key result
Allometric scaling of flow-mediated dilation did not effectively correct for baseline diameter variation compared to traditional calculation in healthy young and older adults.
Why the study?
Does allometric scaling of flow-mediated dilation improve the assessment of endothelial function compared to traditional calculation in healthy adults?
Cross-Sectional (n=35)
Does allometric scaling of flow-mediated dilation improve the assessment of endothelial function compared to traditional calculation in healthy adults?
Allometric scaling of FMD should be used with caution as current methods either produce unexpectedly large values or fail to effectively correct for baseline diameter variations.
Allometric scaling of FMD warrants caution in endothelial assessment; challenges its correction of baseline diameter and leaves open need for validated methods.
Summary Flow‐mediated dilation ( FMD ) is calculated as the greatest percent change in arterial diameter following an ischaemic challenge. This Traditional % FMD calculation is thought to have statistical bias towards baseline diameter (D base ), which is reduced by allometric scaling. This study examined whether allometric scaling FMD influenced the difference between a group of healthy young and older adults compared to the Traditional % FMD , and to determine whether a New (allometric) scaling % FMD improved the ability to obtain individually scaled FMD . Popliteal artery FMD was assessed in 18 young (26 ± 3 years) and 17 older adults (77 ± 5 years). ‘Corrected’ mean FMD was generated from a log‐linked ANCOVA model. Individual % FMD was evaluated using three calculations: (1) Traditional % FMD calculation; (2) Atkinson (allometric) scaling % FMD (peak diameter ); and (3) New scaling % FMD . Traditional % FMD was significantly larger in young (5·82 ± 2·58%) versus old (3·72 ± 1·26%). ‘Corrected’ FMD means (Y: 5·97 ± 2·12%; O: 3·98 ± 2·06%) were similar to Traditional % FMD ; however, the logarithmic transformation prevents statistical interpretation of group differences. Individually scaled % FMD using the Atkinson scaling resulted in values that were corrected for variations in D base but that were twofold to threefold larger than those of the Traditional calculation. New scaling % FMD resulted in values that were similar to values expected (Y: 6·21 ± 2·75%; O: 3·98 ± 1·36%); however, it did not effectively correct for variation in D base . Recommendations regarding the advantages of allometrically scaling % FMD should be made with caution until research clearly establishes the benefits of this approach.
No takes yet. Share an insight, caveat, or question.
McLay et al. (2017) conducted a cross-sectional in Healthy adults (n=35). Allometric scaling of FMD vs. Traditional % FMD calculation was evaluated on Popliteal artery flow-mediated dilation. Allometric scaling of flow-mediated dilation did not effectively correct for baseline diameter variation compared to traditional calculation in healthy young and older adults.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: