Key points are not available for this paper at this time.
The traditional fault-tolerant procedure usually comprises fault detection and fault tolerance. Fault detection is adopted to locate the specific fault, which increases the complexity and misdiagnosis risk of fault-tolerant systems. This article introduced an adaptive fault-tolerant control for open-phase faults and open-switch faults in dual three-phase permanent magnetic synchronous machine (PMSM) drives. The proposed fault-tolerant scheme is fulfilled by going through three operation states: healthy operation, transient xy open-loop faulty operation, and fault-tolerant operation. The angle of fault-tolerant reference currents on xy plane is obtained from the transient xy open-loop faulty operation. Unified fault-tolerant reference currents of open-circuit faults are built up by using the above reference angle. After the open-circuit faults occur, the unified fault-tolerant reference currents are directly applied to the drive system without fault localization. Experimental results demonstrate a very smooth switching capability of the developed adaptive fault-tolerant control from the faulty operation to the fault-tolerant operation without extra hardware.
Shi et al. (Mon,) studied this question.