Experiments are described in which optical images of small metallic objects were reconstructed from millimeter wave phasigrams (phase-only holograms). Since the well-established term HOLOGRAM introduced first by Gabor implies a "total record," namely of amplitude and phase, the term phase-only hologram would be contradictory. The authors propose the term PHASIGRAM for a "phase record" based on the Greek work "phasis" for phase. Sufficient resolution is present in the images obtained to allow the identification of a toy metallic gun, even when covered with a layer of clothing or synthetic leather. The phase distribution of the 70-GHz millimeter wave field scattered by the object was determined by mechanically scanning a harmonic mixer over a 0.75-m diameter circular aperture in a spiral pattern. The resulting electrical phase signal was converted to a light intensity pattern which was recorded on photographic film. A He-Ne laser was used to illuminate a reduced transparency replica of the recorded phasigrams and reconstruct the images.
No takes yet. Share an insight, caveat, or question.
Farhat et al. (1971) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: