Key result
A novel face-based heart rate monitoring technique using the Hilbert-Huang transform outperformed the current state of the art, providing greater measurement accuracy with smaller variance.
Why the study?
Does image sensor-based heart rate evaluation from face reflectance using Hilbert-Huang transform improve measurement accuracy compared to current state of the art?
Does image sensor-based heart rate evaluation from face reflectance using Hilbert-Huang transform improve measurement accuracy compared to current state of the art?
Answers are grounded in this paper and cite their sources.
A novel contactless face-based heart rate monitoring technique using the Hilbert-Huang transform demonstrates improved measurement accuracy and reduced variance compared to existing methods.
Monitoring heart rates using conventional electrocardiogram equipment requires patients to wear adhesive gel patches or chest straps that can cause skin irritation and discomfort. Commercially available pulse oximetry sensors that attach to the fingertips or earlobes also cause inconvenience for patients and the spring-loaded clips can be painful to use. Therefore, a novel robust face-based heart rate monitoring technique is proposed to allow for the evaluation of heart rate variation without physical contact with the patient. Face reflectance is first decomposed from a single image and then heart rate evaluation is conducted from consecutive frames according to the periodic variation of reflectance strength resulting from changes to hemoglobin absorptivity across the visible light spectrum as heartbeats cause changes to blood volume in the blood vessels in the face. To achieve a robust evaluation, ensemble empirical mode decomposition of the Hilbert-Huang transform is used to acquire the primary heart rate signal while reducing the effect of ambient light changes. Our proposed approach is found to outperform the current state of the art, providing greater measurement accuracy with smaller variance and is shown to be feasible in real-world environments.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2014) studied Heart rate monitoring. Face-based heart rate monitoring technique using image sensors and Hilbert-Huang transform vs. Current state of the art was evaluated on Measurement accuracy and variance. A novel face-based heart rate monitoring technique using the Hilbert-Huang transform outperformed the current state of the art, providing greater measurement accuracy with smaller variance.