Key result
Acute changes in gravity altered QRS voltage, with R wave amplitude in Z lead increasing by a mean of 0.19 mV during hypergravity and decreasing by 0.24 mV during microgravity in upright position.
Why the study?
Does acute change of gravity and subsequent intrathoracic blood redistribution alter ECG QRS voltage in healthy volunteers?
Does acute change of gravity and subsequent intrathoracic blood redistribution alter ECG QRS voltage in healthy volunteers?
Acute changes in gravity and intrathoracic blood volume significantly alter ECG QRS voltage, highlighting the impact of body fluid redistribution on ECG interpretation.
Answers are grounded in this paper and cite their sources.
May confound QRS voltage interpretation with fluid shifts; leaves open relevance beyond healthy volunteers.
BACKGROUND: It is known that electroconduction of intrathoracic organs and tissues significantly influences the ECG voltage. It changes during therapy or exercise test due to redistribution and/or volume variations of blood and body fluids and their electroconductivity variations. This fact must be taken into consideration during interpretation of corresponding ECG. But there are no quantitative estimations of this influence on human ECG. The goals of this study were to estimate the influence of variations of thoracic electroconduction, and heart volume on QRS voltage in humans, due to gravity change. METHODS: ECGs of 26 healthy volunteers were analyzed in upright and supine position. Experimental conditions-acute change of gravity--are created in a special aircraft flying on Kepler's parabola trajectory. Each parabola includes phases of normo-, hypergravity (blood shifts in caudal direction), and microgravity (blood redistributes in cranial direction). Amplitude of QRS in Frank leads in all phases has been analyzed. 2-D echo studies for six subjects were used for estimation of heart volume change. RESULTS: In an upright position during hypergravity the amplitude of R wave in Z increases in 95% of cases (mean 0.19 mV). During microgravity amplitude of R wave in Z decreases in 95% (mean 0.24 mV). In supine position changes of QRS voltage are not significantly. CONCLUSION: Blood redistribution during gravity change leads to changes of QRS voltage, which is more expressed and steady on R in Z lead: an average near 0.2 mV. It is due to the balance between two factors: (a). changes of degree of short circuiting by variations in the amount of blood in thorax (b). changes of distance between heart and electrodes as a result of change in the position, form, and volume of the heart.
No takes yet. Share an insight, caveat, or question.
Mm et al. (2003) studied Healthy volunteers (n=26). Acute change of gravity vs. Normogravity was evaluated on Amplitude of QRS in Frank leads. Acute changes in gravity altered QRS voltage, with R wave amplitude in Z lead increasing by a mean of 0.19 mV during hypergravity and decreasing by 0.24 mV during microgravity in upright position.
Synapse has enriched 10 related papers. Consider them for comparative context: