Key result
Coronary microembolization significantly reduced left ventricular ejection fraction and coronary flow reserve at 6 hours, both of which recovered by 1 week despite persistent left ventricular dilation.
Why the study?
Does coronary microembolization reduce left ventricular ejection fraction and coronary flow reserve in a swine model?
Does coronary microembolization reduce left ventricular ejection fraction and coronary flow reserve in a swine model?
Coronary microembolization in a swine model causes transient reductions in LVEF and CFR at 6 hours, followed by functional recovery but persistent left ventricular dilation at 1 week.
Answers are grounded in this paper and cite their sources.
Swine model data warrant no clinical changes; leaves open translation of transient LVEF/CFR effects to human coronary disease.
INTRODUCTION: Although coronary microembolization (CME) is a frequent phenomenon in patients undergoing percutaneous coronary intervention, few data are available on the changes in left ventricular ejection fraction (LVEF) and coronary flow reserve (CFR) after CME. MATERIAL AND METHODS: In this study, six miniature swine of either sex (body weight 21-25 kg) were used to prepare a CME model. After coronary angiography, 1.2 × 10(5) microspheres (42 µm) were selectively infused into the left anterior descending artery via an infusion catheter. Left ventricular ejection fraction was evaluated using transthoracic echocardiography; myocardial blood flow was measured using coloured microspheres; and CFR and coronary pressure were measured using Doppler and a pressure wire. RESULTS: Left ventricular ejection fraction was 0.77 ±0.08 at baseline, 0.69 ±0.08 at 2 h, 0.68 ±0.08 at 6 h, and 0.76 ±0.06 at 1 week (2 h vs. baseline p < 0.05; 6 h vs. baseline p < 0.01). After CME, left ventricular end systolic volume (LVESV) and end diastolic volume (LVEDV) were significant larger 1 week later (p < 0.01 for both), while CFR was significantly reduced at 6 h (1.24 ±0.10 at 6 h vs. 1.77 ±0.30 at baseline, p < 0.01) and myocardial blood flow remained unchanged. Serum ET-1 level was significantly higher only at 6 h after CME (6 h vs. baseline p < 0.05). CONCLUSIONS: Reduction of CFR and LVEF is significant at 6 h after CME and recovers 1 week later with left ventricular dilation.
No takes yet. Share an insight, caveat, or question.
Ma et al. (2012) studied Coronary microembolization (n=6). Coronary microembolization vs. Baseline was evaluated on Left ventricular ejection fraction at 6 hours (p=<0.01). Coronary microembolization significantly reduced left ventricular ejection fraction and coronary flow reserve at 6 hours, both of which recovered by 1 week despite persistent left ventricular dilation.