Key result
The presence of a patent foramen ovale (HR 1.79) and left atrial appendage flow velocity <45 cm/s (HR 1.63) independently predicted atrial fibrillation recurrence after cryoballoon ablation.
Why the study?
TEE allows detailed characterization of the AF substrate, but the prognostic value of TEE-derived LA and LAA features for predicting AF recurrence after cryoballoon-based ablation needed assessment.
Do pre-procedural transesophageal echocardiography features (patent foramen ovale and left atrial appendage flow velocity) predict atrial fibrillation recurrence in patients with paroxysmal atrial fibrillation undergoing cryoballoon ablation?
Cohort (n=417)
No
Do pre-procedural transesophageal echocardiography features (patent foramen ovale and left atrial appendage flow velocity) predict atrial fibrillation recurrence in patients with paroxysmal atrial fibrillation undergoing cryoballoon ablation?
Hazard Ratio: 1.79 (95% CI 1.02–3.15)
p-value: p=0.04
The presence of a patent foramen ovale and reduced left atrial appendage flow velocity (<45 cm/s) on pre-procedural TEE are independent predictors of atrial fibrillation recurrence after cryoballoon ablation.
May identify higher-risk patients for closer monitoring; leaves open whether TEE should guide ablation decisions.
BACKGROUND: Transesophageal echocardiography (TEE) allows detailed characterization of atrial fibrillation (AF) substrate and could be valuable for predicting pulmonary vein isolation (PVI) procedure outcomes. AIMS: We aimed at assessing the value of TEE-derived left atrial (LA) and LA appendage (LAA) features as prognostic markers for AF recurrence after cryoballoon-based ablation. METHODS: Patients were enrolled using a prospective database of consecutive PVI procedures performed over a 7-year period. The following TEE-derived parameters were investigated: LAA emptying flow velocity (LAA-FV), the presence of patent foramen ovale (PFO), LA spontaneous echo contrast, and mitral regurgitation. Diagnosis of AF recurrence was based on scheduled and symptoms triggered ECG monitoring. The Cox's regression model and Kaplan-Meier survival curves were applied for statistical analysis. RESULTS: A total of 417 consecutive patients who underwent their first PVI using cryoballoon were analyzed (mean age: 59 years). AF recurrence was noted in 25.7% of patients (median follow-up of 24 months). Four TEE-derived variables had predictive values for AF recurrence: LAA-FV <45 cm/s, presence of PFO at resting state, LA spontaneous echo contrast, and mitral regurgitation. In the multivariable model, apart from the transthoracic echocardiography-derived LA size, two TEE-derived features (LAA-FV <45 cm/s and the presence of PFO) remained as independent predictors. CONCLUSIONS: This study proposed a novel TEE-derived AF recurrence risk factor - the presence of PFO - and confirmed the prognostic value of LAA flow velocity in patients undergoing cryoballoon-based AF ablation. These risk factors could be useful in the global assessment of AF recurrence risk and potentially helpful in planning the ablation strategy.
No takes yet. Share an insight, caveat, or question.
Kiełbasa et al. (2021) conducted a cohort in Paroxysmal atrial fibrillation (n=417). Patent foramen ovale (PFO) and left atrial appendage flow velocity (LAA-FV) <45 cm/s vs. Absence of PFO and LAA-FV ≥45 cm/s was evaluated on Freedom from atrial fibrillation recurrence (first episode >30 seconds after a 3-month blanking period) (HR 1.79, 95% CI 1.02-3.15, p=0.04). The presence of a patent foramen ovale (HR 1.79) and left atrial appendage flow velocity <45 cm/s (HR 1.63) independently predicted atrial fibrillation recurrence after cryoballoon ablation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: