Key result
A decision support intervention for patients facing ICD replacement was feasible to deliver and improved patient knowledge compared to usual care (77.4% vs 51.1%; P=.002).
Why the study?
Decision support can help patients facing ICD replacement understand options and make informed decisions reflective of their preferences, but feasibility required evaluation.
Does a decision support intervention improve knowledge and decision quality in patients approaching ICD battery depletion?
RCT (n=30)
randomized
Does a decision support intervention improve knowledge and decision quality in patients approaching ICD battery depletion?
A decision support intervention is feasible and significantly improves knowledge among patients facing ICD replacement.
Supports decision support use before ICD replacement; extends RCT evidence for knowledge-focused tools in device decisions.
BACKGROUND: Decision support can help patients facing implantable cardioverter-defibrillator (ICD) replacement understand their options and reach an informed decision reflective of their preferences. OBJECTIVE: The aim of this study was to evaluate the feasibility of a decision support intervention for patients faced with the decision to replace their ICD. METHODS: A pilot feasibility randomized trial was conducted. Patients approaching ICD battery depletion were randomized to decision support intervention or usual care. Feasibility outcomes included recruitment rates, intervention use, and completeness of data; secondary outcomes were knowledge, values-choice concordance, decisional conflict, involvement in decision making, and choice. RESULTS: A total of 30 patients were randomized to intervention (n = 15) or usual care (n = 15). The intervention was used as intended, with 2% missing data. Patients in the intervention arm had better knowledge (77.4% vs 51.1%; P = .002). By 12 months, 8 of 13 (61.5%) in the intervention arm and 10 of 14 (71.4%) in the usual care arm accepted ICD replacement; 1 per arm declined (7.7% vs 7.1%, respectively). CONCLUSION: It was feasible to deliver the intervention, collect data, despite slow recruitment. The decision support intervention has the potential to improve ICD replacement decision quality.
No takes yet. Share an insight, caveat, or question.
Lewis et al. (2020) conducted an RCT in Implantable cardioverter-defibrillator (ICD) battery depletion (n=30). Decision support intervention vs. Usual care was evaluated on Feasibility outcomes including recruitment rates, intervention use, and completeness of data. A decision support intervention for patients facing ICD replacement was feasible to deliver and improved patient knowledge compared to usual care (77.4% vs 51.1%; P=.002).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: