Why the study?
What are the characteristics of intracardiac potentials that indicate an optimal site for catheter ablation in patients with concealed Wolff-Parkinson-White syndrome?
What are the characteristics of intracardiac potentials that indicate an optimal site for catheter ablation in patients with concealed Wolff-Parkinson-White syndrome?
In concealed Wolff-Parkinson-White syndrome, an atrial insertion site exhibiting a multipeak complex electrogram with a high AV ratio indicates an optimal target for successful catheter ablation.
Answers are grounded in this paper and cite their sources.
May guide ablation site selection in concealed WPW; hypothesis-generating case report requiring confirmation.
The authors investigated bipolar electrograms recorded from the catheter tip at the actual successful ablation sites in 22 consecutive patients with concealed Wolff-Parkinson-White syndrome to clarify the characteristics of the potentials indicating the optimal site for catheter ablation. In all patients the retrograde transaortic approach to their left-sided accessory pathways, and a temperature-controlled (60 degrees C) energy delivery, were performed. The authors assumed that a shorter dissociation time (time from energy delivery to ventriculoatrial conduction dissociation) indicated more accurate catheter mapping. A significant negative correlation (r = 0.527, p < 0.05) between the AV ratio (ratio of the amplitudes of the atrial to ventricular potentials) recorded at the ablation catheter tip and the dissociation time was observed. When the AV ratio and the dissociation time were compared among the groups classified according to the corresponding Npeak (the number of positive potential peaks in the electrogram obtained from the ablation catheter tip during right ventricular apical pacing) value, they differed significantly (p < 0.05 and p < 0.01, respectively), ie, a higher AV ratio and a shorter dissociation time related to a multipeak electrogram from the ablation catheter tip. The authors conclude that the atrial insertion site of the accessory pathway, exhibiting a multipeak complex electrogram that may represent nonuniform anisotropic characteristics, is an adequate ablation site.
No takes yet. Share an insight, caveat, or question.
Kawamura et al. (1999) studied this question.