The input-dependent stability observed during torque control experiments using the first joint of the Darmstadt-HAND is discussed. Friction and compliance existing in tendon-sheath drive systems introduce a hysteresis nonlinearity between the joint torque output and the actuator displacement. Although this transmission characteristic is close to the well-known backlash behavior of the gears situated between a motor and a load shift, this hysteresis loop exhibits input-dependent characteristics in the backlash region of the transmission system, with springlike behavior within a portion of the backlash region. Experiments confirmed that there is a close relationship between the input-dependent backlash characteristics and the input-dependent stability. Based on these experiments, the authors describe the transmission characteristic using a simple model and explore the system stability using sinusoidal-input-describing-functions (SIDF). A nondimensional stability-criterion-map that successfully predicts the experimental results is presented.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
No takes yet. Share an insight, caveat, or question.
Kaneko et al. (1992) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: