Key result
Depression in veterans with implantable cardioverter defibrillators was associated with an increased risk of mortality or heart failure hospitalization (adjusted HR 1.25; 95% CI 1.05-1.49).
Why the study?
Does depression increase the risk of mortality or heart failure hospitalization in veterans with implantable cardioverter defibrillators?
Cohort (n=3,862)
Does depression increase the risk of mortality or heart failure hospitalization in veterans with implantable cardioverter defibrillators?
Depression is prevalent among veterans with ICDs and is independently associated with more severe heart failure functional class and an increased risk of mortality or heart failure hospitalization.
Answers are grounded in this paper and cite their sources.
May support depression screening in veterans with ICDs; hypothesis-generating for treatment effects on outcomes.
BACKGROUND: The impact of depression on outcome in implantable cardioverter defibrillator (ICD) recipients has not been fully appreciated. We assessed the prevalence of depression and its association with heart failure (HF) outcome among veterans with ICDs. METHODS AND RESULTS: Patients enrolled between January 2005 and January 2010 in the Outcomes among Veterans with Implantable Defibrillators Registry were studied. We examined the cross-sectional association of depression with severity of HF functional class as well as the association of depression with the composite outcome of mortality or HF hospitalization over a mean follow-up time of 2.7 years. There were 3,862 patients enrolled. Patients with depression (1,162, 43%) were younger (63.1 ± 9.4 years vs 66.6 ± 9.9 years, P < 0.001), more likely to have a history of tobacco or alcohol abuse (P < 0.0001) or atrial fibrillation (P = 0.05) while having a higher ejection fraction (28.3% vs 27.4%, P = 0.03). Depression was associated with advanced HF class at time of implant; odds ratio (OR; vs class I) for class III: 1.65 (confidence interval [CI] 1.17-2.33), class IV: 1.73 (95% CI 1.08-2.76). Death or HF hospitalization was more likely to occur in patients with depression (35.2% vs 32.0%, HR: 1.15 [95% CI 0.99-1.33]). The predictive value of depression was stronger after multivariable adjustment; HR: 1.25 (95% CI 1.05-1.49). CONCLUSION: Depression was prevalent among veterans with ICDs. Depression was associated with severity of HF. The predictive value of associated depression was significant after multivariable adjustment.
No takes yet. Share an insight, caveat, or question.
Shalaby et al. (2014) conducted a cohort in Implantable cardioverter defibrillators (ICDs) (n=3,862). Depression vs. No depression was evaluated on Composite outcome of mortality or HF hospitalization (HR 1.25, 95% CI 1.05-1.49). Depression in veterans with implantable cardioverter defibrillators was associated with an increased risk of mortality or heart failure hospitalization (adjusted HR 1.25; 95% CI 1.05-1.49).
Synapse has enriched 10 related papers. Consider them for comparative context: