Key result
Tendyne transcatheter mitral valve replacement shows feasibility and eliminates paravalvular leak after prior TAVI.
Why the study?
Combined aortic and mitral disease in nonsurgical candidates poses diagnostic and management challenges, especially when staged percutaneous options such as transcatheter mitral valve implantation after TAVI are required.
Does transcatheter mitral valve implantation using the Tendyne valve improve symptoms and valve function in a patient with severe mitral regurgitation and prior TAVI?
Case Report (n=1)
Does transcatheter mitral valve implantation using the Tendyne valve improve symptoms and valve function in a patient with severe mitral regurgitation and prior TAVI?
TMVI using the Tendyne valve is a feasible alternative for treating severe MR in patients with prior TAVI who are unsuitable for edge-to-edge repair.
Background: The presence of aortic and mitral disease in a patient who is not a suitable candidate for surgical correction poses significant challenges in the diagnostic workup as well as management plans. Percutaneous treatment can be staged to fix the aortic valve with transcatheter aortic valve implantation (TAVI) as a first step, followed by reassessment and percutaneous correction of mitral regurgitation (MR). Case summary: A 65-year-old female with multiple co-morbidities presented with acute coronary syndrome and heart failure. She was diagnosed with three-vessel coronary artery disease and degenerative low-flow low-gradient severe aortic stenosis, along with severe degenerative MR with a left ventricular ejection fraction of 35%. Because of the high surgical risk, she underwent multi-vessel percutaneous coronary intervention with stenting. Transcatheter aortic valve implantation was done as a staged procedure, which partially improved her symptoms. Mitral regurgitation was not suitable for percutaneous mitral valve edge-to-edge repair. After a discussion by the heart team, she underwent transcatheter mitral valve implantation, for which the Tendyne mitral valve (Tendyne™; Abbott) was used through a transapical approach. There was no paravalvular leak, and the mean gradient across the valve was 2 mmHg. She was symptomatically better at follow-up and an echocardiogram showed a normally functioning aortic valve and Tendyne mitral valves. Discussion: Transapical transcatheter mitral valve implantation using the Tendyne valve is a feasible option for patients with prior TAVI. This can be considered an alternative treatment for MR in patients who are not suitable for edge-to-edge mitral repair.
No takes yet. Share an insight, caveat, or question.
Shah et al. (2023) conducted a case report in Severe degenerative mitral regurgitation with prior TAVI (n=1). Transcatheter mitral valve implantation (Tendyne mitral valve system) was evaluated on Procedural success and valve function (paravalvular leak and mean gradient). Transcatheter mitral valve implantation using the Tendyne valve is a feasible option that resulted in no paravalvular leak and improved symptoms in a patient with a prior TAVI.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: