Key result
Tricuspid annular E/E' ratio strongly correlated with invasive right atrial pressure (r=0.84, P<0.001); a ratio ≥4.5 provided 89% sensitivity and 100% specificity for elevated RAP.
Why the study?
Does conventional and tissue Doppler echocardiography accurately estimate invasively measured right atrial pressure in patients in sinus rhythm?
Observational (n=50)
Does conventional and tissue Doppler echocardiography accurately estimate invasively measured right atrial pressure in patients in sinus rhythm?
Effect estimate: r = 0.84
p-value: p=< 0.001
The tricuspid annular E/E' ratio is a highly sensitive and specific noninvasive echocardiographic marker for estimating right atrial pressure.
May support noninvasive RAP estimation in sinus rhythm; leaves open prospective validation before clinical adoption.
BACKGROUND: Evaluation of right atrial pressure (RAP) provides useful diagnostic, therapeutic, and prognostic information. AIM: To assess the utility of several conventional and tissue Doppler parameters in the estimation of RAP. METHODS: Among 50 consecutive patients (median age: 50 years; all in sinus rhythm), invasively measured RAP was simultaneously correlated with pulsed Doppler of tricuspid inflow (peak E and A velocities, E-wave deceleration time) and pulsed tissue Doppler of lateral tricuspid annulus (peak E' and A' velocities, isovolumic relaxation time [IVRT], acceleration time and rate of E'-wave, deceleration time and rate of E'-wave). These ratios were calculated: E/A, E'/A', E/E', and E/IVRT. RESULTS: The median RAP was 14 mmHg (range 1-27 mmHg) with 29 patients (58%) having an elevated RAP (>10 mmHg). Among all studied Doppler variables, E/E' ratio showed the strongest correlation with RAP (r = 0.84, P < 0.001) with the following regression equations: RAP = 1.24 + (1.69 × E/E'). The mean difference between Doppler and invasively measured RAP was 0.21 ± 2.6 mmHg. E/ E' ratio ≥ 4.5 provides 89% sensitivity and 100% specificity for detection of elevated RAP (receiver operating characteristic area 0.95; P < 0.001). CONCLUSION: Of all echocardiographic variables investigated, tricuspid annular E/E' ratio is identified as the best index for noninvasive determination of RAP.
No takes yet. Share an insight, caveat, or question.
Said et al. (2012) conducted an observational in Elevated right atrial pressure (n=50). Conventional and tissue Doppler echocardiography vs. Invasively measured right atrial pressure was evaluated on Correlation with invasively measured right atrial pressure (r = 0.84, p=< 0.001). Tricuspid annular E/E' ratio strongly correlated with invasive right atrial pressure (r=0.84, P<0.001); a ratio ≥4.5 provided 89% sensitivity and 100% specificity for elevated RAP.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: