Why the study?
Does induction of general anaesthesia with sufentanil and positive-pressure ventilation alter intra- to extrathoracic volume distribution in patients undergoing coronary bypass grafting?
Does induction of general anaesthesia with sufentanil and positive-pressure ventilation alter intra- to extrathoracic volume distribution in patients undergoing coronary bypass grafting?
Induction of general anaesthesia with sufentanil and positive-pressure ventilation causes a significant blood volume shift from intra- to extrathoracic compartments, decreasing cardiac filling and justifying generous intravenous fluid administration.
Induction may shift volume extrathoracically and reduce filling in CABG patients; hypothesis-generating for fluid strategies, should not yet change practice.
Background and objective: Induction of general anaesthesia in combination with positive-pressure ventilation is often associated with a significant decrease of arterial pressure. A decreased preload may contribute to this phenomenon. The aim was to investigate whether a change in cardiac filling occurs following the induction of general anaesthesia with sufentanil under typical clinical conditions. Methods: Fifteen patients scheduled for elective coronary bypass grafting were studied immediately before surgery. In addition to standard monitors, a transpulmonary double-indicator dilution technique measured in vivo intrathoracic blood volume, global end-diastolic volume and total circulating blood volume. For induction of anaesthesia 2 μg kg−1 sufentanil was given. Measurements were performed awake and after the induction of anaesthesia, intubation and mechanical ventilation of the lungs. Results: To maintain arterial pressure during the induction period within −20% of baseline pressure, on average 22 ± 6 mL kg−1 crystalloids and 8 ± 6 mL kg−1 colloids were given. Despite these amounts of fluid, cardiac filling was decreased, whereas circulating blood volume increased significantly. Both central venous pressure and pulmonary capillary wedge pressure increased. Conclusions: Induction of general anaesthesia with positive-pressure ventilation is regularly associated with a blood volume shift from intra- to extrathoracic compartments. Even in low-dose opioid monoanaesthesia with sufentanil - often regarded as relatively inert in haemodynamic terms - the phenomenon could be demonstrated as the primary cause of the often-observed decrease of arterial pressure. It seems, therefore, rationally justified to restore cardiac filling by generous administration of intravenous fluids, at least in patients with unaffected cardiac pump function. During induction of anaesthesia, central venous pressure and pulmonary capillary wedge pressure do not reliably indicate cardiac filling.
No takes yet. Share an insight, caveat, or question.
Spiegel et al. (2002) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: