Key result
In a swine model, the pacing interval for ventricular fibrillation induction was positively correlated with the maximal slope of the activation-recovery interval restitution curve of the right ventricular apex (r = 0.761, p < 0.05).
Effect estimate: r = 0.761
p-value: p=<0.05
In a swine model, the pacing interval for ventricular fibrillation induction is related to the maximal slope of the ARI restitution curve at the right ventricular apex, while pacing strength is associated with spatial dispersions of ARI and its restitution property.
Hypothesis-generating for VF mechanisms in swine; leaves open human translation and clinical relevance.
INTRODUCTION: The roles of pacing interval (PI) and pacing strength (PS) in ventricular fibrillation (VF) induced by rapid pacing with 1 : 1 capture remain unclear. MATERIAL AND METHODS: Epicardial unipolar electrograms (UEs) were simultaneously recorded using contact mapping in 11 swine. Activation-recovery interval (ARI) restitution was constructed at 4 sites, i.e. the apex and base of the left and right ventricles, respectively. A steady state pacing (SSP) protocol was performed to induce VF. The longest PI and the lowest PS for inducing VF were recorded. Statistical correlation analysis was performed to determine the relationship between local ARI restitution properties and PI and PS for VF induction. RESULTS: Forty restitution curves were constructed from 11 SSP procedures. The maximal slope (Smax) of the ARI restitution curve of the right ventricular apex was positively correlated with the PI for VF induction (r = 0.761, p < 0.05). Spatial dispersions of ARI and Smax were negatively correlated with the PS for VF induction (r = -0.626 and r = -0.722, respectively, both p < 0.05). CONCLUSIONS: Ventricular fibrillation can be induced by rapid ventricular pacing with 1 : 1 capture. The PI for VF induction was related to the Smax of the ARI restitution curve of the right ventricular apex, while PS for VF induction was associated with the spatial dispersions of ARI and its restitution property.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2015) studied Ventricular fibrillation (n=11). Rapid ventricular pacing with 1:1 capture was evaluated on Correlation between maximal slope (Smax) of the activation-recovery interval restitution curve of the right ventricular apex and pacing interval for VF induction (r = 0.761, p=<0.05). In a swine model, the pacing interval for ventricular fibrillation induction was positively correlated with the maximal slope of the activation-recovery interval restitution curve of the right ventricular apex (r = 0.761, p < 0.05).