Key result
An experimental pipeline using diffusion tensor magnetic resonance imaging can construct and validate anisotropic and orthotropic ventricular geometries for predictive cardiac electrophysiology models.
The study presents a pipeline combining DT-MRI and computational modeling to construct and validate ventricular geometries for predicting cardiac electrophysiology and arrhythmia initiation.
DT-MRI pipeline validates orthotropic geometries in animals; leaves open human translation for arrhythmia prediction.
Reaction-diffusion computational models of cardiac electrophysiology require both dynamic excitation models that reconstruct the action potentials of myocytes as well as datasets of cardiac geometry and architecture that provide the electrical diffusion tensor D, which determines how excitation spreads through the tissue. We illustrate an experimental pipeline we have developed in our laboratories for constructing and validating such datasets. The tensor D changes with location in the myocardium, and is determined by tissue architecture. Diffusion tensor magnetic resonance imaging (DT-MRI) provides three eigenvectors e(i) and eigenvalues λ(i) at each voxel throughout the tissue that can be used to reconstruct this architecture. The primary eigenvector e(1) is a histologically validated measure of myocyte orientation (responsible for anisotropic propagation). The secondary and tertiary eigenvectors (e(2) and e(3)) specify the directions of any orthotropic structure if λ(2) is significantly greater than λ(3)-this orthotropy has been identified with sheets or cleavage planes. For simulations, the components of D are scaled in the fibre and cross-fibre directions for anisotropic simulations (or fibre, sheet and sheet normal directions for orthotropic tissues) so that simulated conduction velocities match values from optical imaging or plunge electrode experiments. The simulated pattern of propagation of action potentials in the models is partially validated by optical recordings of spatio-temporal activity on the surfaces of hearts. We also describe several techniques that enhance components of the pipeline, or that allow the pipeline to be applied to different areas of research: Q ball imaging provides evidence for multi-modal orientation distributions within a fraction of voxels, infarcts can be identified by changes in the anisotropic structure-irregularity in myocyte orientation and a decrease in fractional anisotropy, clinical imaging provides human ventricular geometry and can identify ischaemic and infarcted regions, and simulations in human geometries examine the roles of anisotropic and orthotropic architecture in the initiation of arrhythmias.
No takes yet. Share an insight, caveat, or question.
Benson et al. (2010) studied Cardiac electrophysiology. Experimental pipeline using DT-MRI was evaluated. An experimental pipeline using diffusion tensor magnetic resonance imaging can construct and validate anisotropic and orthotropic ventricular geometries for predictive cardiac electrophysiology models.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: