Key result
Preprocedural plaque volume was significantly greater in patients with filter no-reflow than those without (355 ± 133 vs. 199 ± 90 mm3, P=0.0004) and independently predicted distal embolization.
Why the study?
Does preprocedural plaque volume and tissue characterization by IB-IVUS predict distal embolization during PCI in patients with unstable angina?
Observational (n=39)
Does preprocedural plaque volume and tissue characterization by IB-IVUS predict distal embolization during PCI in patients with unstable angina?
Preprocedural plaque volume measured by IVUS is a significant independent predictor of distal embolization during PCI for unstable angina.
Greater plaque volume by IVUS was associated with distal embolization; hypothesis-generating for risk stratification in unstable angina PCI.
Objectives We performed microscopic examination of the debris collected by a distal protection device and investigated the usefulness of grayscale and integrated backscatter intravascular ultrasound (IB‐IVUS) for the prediction of distal embolization during percutaneous coronary intervention (PCI) in cases of unstable angina. Background The prediction of distal embolization during PCI has not been studied in depth because assessment of distal embolization is difficult. Methods We prospectively studied 39 consecutive patients with unstable angina who underwent PCI with a filter distal protection device. The preprocedural plaque volume at target lesions was measured with grayscale IVUS and plaque characteristics were assessed with IB‐IVUS. We performed microscopic examination of the particles collected by the distal protection device. Results There was a significant correlation between the plaque volume and the number of the collected particles >100 μm in diameter ( r = 0.48, P = 0.0034). Filter no‐reflow (FNR) phenomenon was found in nine patients. The plaque volume was significantly greater (355 ± 133 mm 3 vs. 199 ± 90 mm 3 , P = 0.0004), and the lipid ratio was significantly higher (29.3 ± 4.3% vs. 26.1 ± 4.3 P = 0.045) in the FNR group compared with the non‐FNR group. Multivariate logistic regression analysis showed that the plaque volume was an independent predictor of FNR phenomenon. Conclusions Although tissue characterization of IB‐IVUS may provide additional information for distal embolization, plaque volume is the only significant predictor of distal embolization during PCI.
No takes yet. Share an insight, caveat, or question.
Shibuya et al. (2012) conducted an observational in Unstable angina (n=39). Preprocedural plaque volume and characteristics assessed by IVUS vs. Lower plaque volume / non-FNR was evaluated on Filter no-reflow (FNR) phenomenon (p=0.0004). Preprocedural plaque volume was significantly greater in patients with filter no-reflow than those without (355 ± 133 vs. 199 ± 90 mm3, P=0.0004) and independently predicted distal embolization.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: