Key result
Distal protection during PCI preserves TIMI 3 flow, capturing fibrin- and collagen-rich plaque debris.
Why the study?
Histopathological analysis of embolic debris captured during PCI is rarely reported and may provide insights into the relationship between plaque characteristics and coronary flow outcomes.
Case Report (n=1)
This case demonstrates that the histological composition of embolic debris may lack abundant lipid components despite extensive IVUS attenuation, highlighting the multifactorial nature of the no-reflow phenomenon.
Histopathological debris analysis in no-reflow may link IVUS attenuation to embolization; leaves open whether it informs targeted PCI strategies.
Background The no-reflow phenomenon during percutaneous coronary intervention (PCI) is commonly associated with distal embolization from high-risk coronary plaques, including lesions with intravascular ultrasound (IVUS)-defined attenuation. Histopathological analysis of embolic debris captured during PCI is rarely reported and may provide additional insights into the relationship between plaque characteristics and coronary flow outcomes. Case Summary An 84-year-old man presented with acute coronary syndrome and decompensated heart failure. Coronary angiography demonstrated severe multivessel coronary artery disease, including a long right coronary artery lesion with extensive IVUS attenuation. Given the high risk of distal embolization, PCI was performed using a distal protection device. Drug-eluting stents were successfully implanted, and TIMI flow grade 3 was maintained throughout the procedure without slow-flow or no-reflow. Histopathological examination of debris captured by the distal protection device demonstrated predominantly fibrin- and collagen-rich thrombotic material with macrophage infiltration and no apparent abundant lipid component. The patient experienced an uneventful recovery and was discharged without procedural complications. Conclusion The composition of retrieved embolic debris captured during PCI differed from the expected imaging phenotype. This case highlights the potential discrepancy between intracoronary imaging appearance and embolized material and underscores the multifactorial nature of coronary slow-flow and no-reflow. Careful interpretation of IVUS attenuation and embolic pathology is warranted when assessing procedural risk.
No takes yet. Share an insight, caveat, or question.
Suzuki et al. (2026) conducted a case report in Acute coronary syndrome and decompensated heart failure (n=1). PCI with a distal protection device was evaluated on Procedural coronary flow outcomes and histopathological composition of embolic debris. PCI with a distal protection device in an 84-year-old man with an IVUS-attenuated plaque maintained TIMI flow grade 3, capturing fibrin- and collagen-rich debris without abundant lipid.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: