Highlights the early complications of surgically implanted electronic pacemakers for complete heart block and proposes the concept of a naturally occurring conduction bypass.
THE SURGICAL implantation of electronic pacemakers to correct varying degrees of heart block has not met with unqualified success. Battery decay, hermetic seal leakage, electrode dislodgement, wire breakage, infection, and fatal arrhythmias have been but a few of the complications reported.¹⁻⁴Since the first pioneers introduced implantable cardiac pacemakers⁵⁻⁷in the initial part of this decade, the incidence of such technical difficulties has been markedly reduced. Nevertheless, some of the earliest reports⁸⁻¹⁰still stand to remind the surgeon that a very gross foreign body is being traumatically introduced into a precarious myocardial environment. The use of a naturally occurring conduction by-pass would seem to be fraught with less tribulation and provide a more reasonable approach to longterm survival in patients with medically intractable heart block. Classical observations in the "heart-lung" preparations and later with the electrocardiogram enabled early students of cardiac function to state that seemingly normal
No takes yet. Share an insight, caveat, or question.
John H. Mayer (1967) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: