Post-TAVR pacemaker implantation impairs early quality of life but shows no link to 1-year outcomes.
Why the study?
Does permanent pacemaker implantation reduce quality of life in patients who have undergone transcatheter aortic valve replacement?
Cohort (n=383)
No
Does permanent pacemaker implantation reduce quality of life in patients who have undergone transcatheter aortic valve replacement?
Answers are grounded in this paper and cite their sources.
Post-TAVR permanent pacemaker implantation transiently lowers quality of life at 1 month but causes no significant long-term impairment, though poor early QoL itself strongly predicts 1-year mortality.
Background Permanent pacemaker implantation is the most common complication after Transcatheter aortic valve replacement (TAVR) and is associated with worse outcomes and mortality. However, its impact on quality‐of‐life (QoL) outcomes remains unknown. Methods We included 383 consecutive patients undergoing TAVR from January 2012 to 2016 who completed a baseline Kansas City Cardiomyopathy Questionnaire (KCCQ‐12) health survey. The clinical, laboratory, angiographic, QoL, mortality, and occurrence of poor outcomes (KCCQ‐12 score < 45 or KCCQ decrease of ≥10 points) were obtained. Results The mean age was 83 ± 8 years, 51% were men, and majority were Caucasians (n = 364, 95%). Permanent pacemaker (PPM) was implanted in 11.5% of patients post‐TAVR. PPM patients were more likely to have prior conduction disease including RBBB (25% vs 12%, P = .02) and PQ interval >250 ms (11% vs 5%, P = .07). One‐month median KCCQ‐12 scores were significantly lower among PPM patients (84.7 vs 68.8, P = .04), but did not differ significantly at 1‐year (86.5 vs 90.6, P = .5) post‐TAVR. Occurrence of poor outcomes did not differ significantly among those with or without PPM at 1 month (11% vs 7%, P = .39) and 1 year (13% vs 9%, P = .45), respectively. However, patients with poor QoL outcomes at 1 month post‐TAVR also had significantly worse mortality during follow‐up in unadjusted (31.3% vs 4.5%, P < .001) and adjusted (HR = 5.30, 95% [CI: 1.85‐15.22, P = .002])analyses, respectively. Conclusion Permanent pacemaker implantation is associated with short‐term reduction in QoL without long‐term implications post‐TAVR. Patients with poor QoL post‐TAVR also have significantly higher mortality.
No takes yet. Share an insight, caveat, or question.
Bhardwaj et al. (2018) conducted a cohort in Severe aortic stenosis undergoing TAVR (n=383). Permanent pacemaker implantation post-TAVR vs. No permanent pacemaker implantation post-TAVR was evaluated on Poor QoL outcome (KCCQ-12 score < 45 or decrease of ≥10 points) at 1 year post-TAVR (OR 2.04, 95% CI 0.68-6.11, p=0.21). Permanent pacemaker implantation post-TAVR is associated with short-term (1-month) reductions in quality of life but no significant difference in poor QoL outcomes at 1 year.