Key result
An attentive RNN-based network fusing 12-lead ECG and clinical features achieved an overall diagnostic accuracy of 98.3% for myocardial infarction on the PTB database.
Why the study?
Existing automated 12-lead ECG methods may not provide reliable myocardial infarction diagnosis in the presence of mimicking cardiac diseases.
Does fusing 12-lead ECG with clinical features using an attentive RNN-based network improve the diagnostic accuracy of myocardial infarction?
Does fusing 12-lead ECG with clinical features using an attentive RNN-based network improve the diagnostic accuracy of myocardial infarction?
Fusing 12-lead ECG data with clinical features using an attentive RNN-based network achieves 98.3% accuracy for diagnosing myocardial infarction, potentially aiding pre-screening in crowded hospitals.
May aid MI pre-screening in high-volume settings; extends ECG-only models via attentive clinical feature fusion.
The diagnosis of myocardial infarction (MI) in the presence of other cardiac diseases having similar electrocardiogram (ECG) characteristics that of MI is a challenging problem. Existing automated methods have used the standard 12-lead ECG to detect MI from healthy controls (HC). However, these methods may not provide reliable MI diagnosis in the presence of mimicking MI diseases. Therefore, in this letter, we incorporate the patients' clinical features, including age, gender, smoking, hypertension and blood lipid levels, to the 12-lead ECG features for improved classification performance. Specifically, the 12-lead ECG is summarized using weights shared recurrent neural network with intra- and inter-lead attention modules. These modules mimic the clinicians way of diagnosis by focusing on the clinically relevant information to obtain an attentive representative vector. Then, the patients' clinical features are fused with the attentive vector to obtain a discriminate high-level representation vector for a reliable diagnosis. The experimental results on the PTB database indicate that the proposed method achieves an improved overall accuracy of 98.3%. The improved diagnostic accuracy obtained by the fusion of clinical features to the 12-lead ECG makes the proposed method suitable for the pre-screening of MI patients in crowded hospitals.
No takes yet. Share an insight, caveat, or question.
Prabhakararao et al. (2020) studied Myocardial infarction. Attentive RNN-Based Network fusing 12-lead ECG and clinical features vs. Standard 12-lead ECG automated methods was evaluated on Overall diagnostic accuracy. An attentive RNN-based network fusing 12-lead ECG and clinical features achieved an overall diagnostic accuracy of 98.3% for myocardial infarction on the PTB database.