Key result
A miniaturized moiré interferometry device achieved 99.1% accuracy in heart rate measurement compared to a commercial ECG system, demonstrating its suitability for non-invasive skin vibration monitoring.
A novel miniaturized device using geometrical moiré interferometry can accurately monitor arterial-induced skin vibration for potential continuous non-invasive blood pressure measurement.
Answers are grounded in this paper and cite their sources.
Supports miniaturization feasibility for skin vibration sensing; leaves open clinical validation for continuous BP monitoring.
The demand for self-measured blood pressure self-monitoring device has much increased due to cardiovascular diseases have become leading causes of death for aging population. Currently, the primary non-invasive blood pressure monitoring method is cuff-based. It is well developed and accurate. However, the measuring process is not comfortable, and it cannot provide a continuous measurement. To overcome this problem, methods such as tonometry, volume clamp method, photoplethysmography, pulse wave velocity, and pulse transit time are reported. However, the limited accuracy hindered its application for diagnostics. To perform sequential blood pressure measurement with a high accuracy and long-term examination, we apply moiré interferometry to measure wrist skin vibration induced by radial artery. To achieve this goal, we developed a miniaturized device that can perform moiré interferometry around the wrist region. The 0.4-mm-pitched binary grating and tattoo sticker with 0.46 mm-pitched stripe pattern are used to perform geometric moiré. We demonstrated that the sensitivity and accuracy of this integrated system were sufficient to monitor arterialinduced skin vibration non-invasively. Our developed system was validated with ECG signals collected by a commercial system. According to our studies from measurement, the repeatability of wrist pulsation measurement was achieved with an accuracy of 99.1% in heart rate. A good repeatability of wrist pulse measurement was achieved. Simulations and experiments are both conducted in this paper and prove of geometrical moiré method a suitable technique for arterial-induced skin vibration monitoring.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2018) studied Blood pressure monitoring. Moiré interferometry device vs. Commercial ECG system was evaluated on Heart rate accuracy. A miniaturized moiré interferometry device achieved 99.1% accuracy in heart rate measurement compared to a commercial ECG system, demonstrating its suitability for non-invasive skin vibration monitoring.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: