Key result
Resistance to blood flow, pressure drop, and wall shear stress increase with the height and length of an overlapping stenosis, while resistance decreases with couple stress fluid parameters.
Answers are grounded in this paper and cite their sources.
Mathematical modeling demonstrates that overlapping arterial stenosis significantly alters hemodynamics, with resistance and pressure drop increasing with stenosis severity and varying with non-Newtonian fluid properties.
The effects of an overlapping stenosis on blood flow characteristics in an artery have been studied. Blood has been represented by a couple stress fluid. The flow equations have been linearised and the expressions for pressure drop, resistance to the flow and wall shear stress have been derived. The results are shown graphically. It is observed that the resistance to the flow, pressure drop and wall shear stress increases with height and length of the stenosis. And it is noticed that the resistance to the flow and pressure drop decreases with couple stress fluid parameters. But wall shear stress increases with couple stress fluid parameters.
No takes yet. Share an insight, caveat, or question.
Prasad et al. (2017) studied Atherosclerosis / Stenosis. Overlapping stenosis and couple stress fluid parameters vs. Normal artery / Newtonian fluid was evaluated on Resistance to flow, pressure drop, and wall shear stress. Resistance to blood flow, pressure drop, and wall shear stress increase with the height and length of an overlapping stenosis, while resistance decreases with couple stress fluid parameters.
Synapse has enriched 10 related papers. Consider them for comparative context: