Key result
The spectrum-based computer-aided tool successfully located the left ventricle in all cases, achieving an average cropping ratio of 0.165.
Why the study?
Does a spectrum-based computer-aided tool improve automatic localization of the left ventricle from cardiac cine MRI in healthy volunteers?
Does a spectrum-based computer-aided tool improve automatic localization of the left ventricle from cardiac cine MRI in healthy volunteers?
A novel spectrum-based computer-aided tool using anisotropic weighted circle Hough transform successfully and automatically locates the left ventricle in cardiac cine MRI, reducing computational load for further segmentation.
Answers are grounded in this paper and cite their sources.
Supports automated LV localization feasibility in volunteers; leaves open validation in patients and segmentation gains.
Traditionally, cardiac image analysis is done manually. Automatic image processing can help with the repetitive tasks, and also deal with huge amounts of data, a task which would be humanly tedious. This study aims to develop a spectrum-based computer-aided tool to locate the left ventricle using images obtained via cardiac magnetic resonance imaging. Discrete Fourier Transform was conducted pixelwise on the image sequence. Harmonic images of all frequencies were analyzed visually and quantitatively to determine different patterns of the left and right ventricles on spectrum. The first and fifth harmonic images were selected to perform an anisotropic weighted circle Hough detection. This tool was then tested in ten volunteers. Our tool was able to locate the left ventricle in all cases and had a significantly higher cropping ratio of 0.165 than did earlier studies. In conclusion, a new spectrum-based computer aided tool has been proposed and developed for automatic left ventricle localization. The development of this technique, which will enable the automatic location and further segmentation of the left ventricle, will have a significant impact in research and in diagnostic settings. We envisage that this automated method could be used by radiographers and cardiologists to diagnose and assess ventricular function in patients with diverse heart diseases.
No takes yet. Share an insight, caveat, or question.
Zhong et al. (2014) studied Healthy volunteers (n=10). Spectrum-based computer-aided tool vs. Earlier methods (historical) was evaluated on Cropping ratio (size ratio of the cropped ROI to the whole image). The spectrum-based computer-aided tool successfully located the left ventricle in all cases, achieving an average cropping ratio of 0.165.
Synapse has enriched 10 related papers. Consider them for comparative context: