Why the study?
Does fuzzy logic-based automatic contour detection correlate with manual tracing for calculating ejection fraction in cardiac cine MRI?
Does fuzzy logic-based automatic contour detection correlate with manual tracing for calculating ejection fraction in cardiac cine MRI?
A fuzzy logic-based automatic contour detection method for cardiac cine MRI shows excellent correlation with manual tracing for calculating ejection fraction, potentially reducing observer variability and time.
Supports automated EF quantification in research; leaves open clinical adoption and workflow impact.
RATIONALE AND OBJECTIVES: Gated cardiac cine magnetic resonance imaging provides accurate dynamic data of the left ventricular function. However, the manual extraction of important physiologic parameters such as myocardium wall thickness and left ventricular volumes is invariably time consuming and subjective. To reduce the variability and time constraints inherent in observer contour tracing, the authors developed an automatic left ventricle contour-detection method. METHODS: The purpose was to apply fuzzy logic-based automatic contour detection to identification of endocardial and epicardial borders in short-axis magnetic resonance images. The automatic contouring was compared with manual tracing using the calculated ejection fraction as the comparison criterion. RESULTS: A good correlation was found between the two approaches (r2 = 0.98). CONCLUSIONS: The ejection fraction can be obtained using this automatic contouring method.
No takes yet. Share an insight, caveat, or question.
Lalande et al. (1999) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: