Key result
GEHC and Hologic DXA systems show substantial agreement for VAT-based metabolic risk classification.
Why the study?
Excess visceral adipose tissue is a major risk factor for metabolic syndrome, but different dual-energy x-ray absorptiometry manufacturers provide different visceral adipose tissue estimates.
Can visceral adipose tissue measures be standardized between GE HealthCare and Hologic DXA systems for metabolic risk classification?
Cross-Sectional (n=129)
Can visceral adipose tissue measures be standardized between GE HealthCare and Hologic DXA systems for metabolic risk classification?
VAT measures from GEHC and Hologic DXA systems can be standardized using simple regression equations, allowing for consistent metabolic risk classification across different imaging systems.
Answers are grounded in this paper and cite their sources.
Supports VAT standardization across DXA systems for metabolic risk classification; leaves open prospective validation before clinical adoption.
OBJECTIVE: Excess visceral adipose tissue (VAT) is a major risk factor for metabolic syndrome (MetS) and clinical guidelines have been proposed to define VAT levels associated with increased risk. The aim was to standardize VAT measures between two dual-energy x-ray absorptiometry (DXA) manufacturers who provide different VAT estimates to support standardization of measures across imaging modalities. METHODS: Scans from 114 individuals (ages 18-81 years) on GE HealthCare (GEHC) and Hologic DXA systems were compared via Deming regression to standardize VAT between the two systems, validated in a separate sample (n = 15), with κ statistics to assess agreement of VAT measurements for classifying patients into risk categories. VAT area measures substantially agreed for metabolic risk classification (weighted κ = 0.76) with no significant differences in the population mean values. CONCLUSIONS: VAT measures can be estimated from GEHC and Hologic scans that classify individuals in a substantially similar way into metabolic risk categories, and systematic bias between the measures can be removed using simple regression equations. These findings allow for DXA VAT measures to be used in complement to other imaging modalities, regardless of whether scans used GEHC or Hologic systems.
No takes yet. Share an insight, caveat, or question.
Bennett et al. (2023) conducted a cross-sectional in Excess visceral adipose tissue (n=129). GE HealthCare (GEHC) DXA system vs. Hologic DXA system was evaluated on Agreement of VAT measurements for classifying patients into metabolic risk categories (weighted κ = 0.76). VAT measures from GEHC and Hologic DXA systems showed substantial agreement for metabolic risk classification with no significant differences in population mean values.