Why the study?
Does dual chamber (DDDR) pacing improve objective exercise parameters compared to single chamber (VVIR) pacing in patients with chronotropic incompetence and left ventricular dysfunction?
Does dual chamber (DDDR) pacing improve objective exercise parameters compared to single chamber (VVIR) pacing in patients with chronotropic incompetence and left ventricular dysfunction?
In the acute setting, dual chamber rate responsive pacing does not provide objective improvements in exercise tolerance or hemodynamics compared to single chamber pacing in patients with chronotropic incompetence and left ventricular dysfunction.
Answers are grounded in this paper and cite their sources.
DDDR offers no exercise or hemodynamic advantage over VVIR; challenges routine dual-chamber preference in chronotropic incompetence with LV dysfunction.
Dual chamber, rate responsive (DDDR) pacing is felt to be superior to ventricular, rate responsive (VVIR) pacing since it more closely mimics the normal electrical and hemodynamic activity of the heart. This reasoning has been used to justify the higher initial costs and increased complexity of dual chamber system. This study was designed to determine if objective criteria could be identified during acute testing justify implanting a dual chamber instead of a single chamber system in patients with left ventricular dysfunction. Eight patients with DDDR pacemakers (implanted for chronotropic incompetence) and left ventricular dysfunction underwent exercise radionuclide angiography and graded exercise treadmill testing. Each patient performed the tests in the single (VVIR) and dual (DDDR) chamber modes in a randomized, blinded fashion. We found that objective parameters such as ejection fraction (31% +/- 13% vs 31% +/- 10%), exercise tolerance (6.1 +/- 2.7 min vs 6.3 +/- 2.9 min), oxygen consumption (VO2) (941 +/- 286 mL/min vs 994 +/- 314 mL/min), carbon dioxide production (VCO2) (995 +/- 332 mL/min vs 1054 +/- 356 mL/min), and maximum attainable workload (43 +/- 24 W vs 46 +/- 22 W) did not differ between the single and dual chamber pacing modes. These findings suggest that in the acute setting, the additional cost and complexity of dual chamber, rate responsive pacing cannot be justified by objective improvements in exercise tolerance in patients with underlying left ventricular dysfunction.
No takes yet. Share an insight, caveat, or question.
Barrington et al. (1995) studied this question.