Key result
Serial 123I-MIBG scintigraphic studies showing a delta washout rate ≥-5% strongly predicted cardiac death in stabilized chronic heart failure patients (HR 4.444; 95% CI 1.511-13.069; P=0.009).
Why the study?
Does serial 123I-MIBG scintigraphy (delta washout rate) better predict cardiac death compared to a one-time scan in stabilized patients with chronic heart failure?
Cohort (n=208)
Does serial 123I-MIBG scintigraphy (delta washout rate) better predict cardiac death compared to a one-time scan in stabilized patients with chronic heart failure?
Hazard Ratio: 4.444 (95% CI 1.511–13.069)
p-value: p=0.009
May refine risk stratification in stabilized chronic HF; hypothesis-generating and requires prospective validation vs single scans before practice change.
BACKGROUND: Many studies have shown a one-time ¹²³I-metaiodobenzylguanidine (MIBG) scan during a stable period to be useful for determining the prognosis of patients with chronic heart failure (CHF). However, we recently reported that the delta washout rate (WR) determined from serial ¹²³I-MIBG scintigraphic studies is the best prognostic value in patients with CHF. METHODS: A total of 208 patients with CHF (left ventricular ejection fraction <45%), but no cardiac events for at least 5 months, were identified on the basis of a history of decompensated acute heart failure requiring hospitalization. The patients underwent ¹²³I-MIBG scintigraphy and echocardiography just before leaving the hospital and after 6 months of treatment. We evaluated two models for predicting cardiac death using the Cox proportional hazards regression analysis. In addition to clinical characteristics, New York Heart Association functional class and pharmacotherapy, one model included variables of baseline scintigraphic and echocardiographic parameters (model A), and the other model included those of delta (i.e. follow-up minus baseline) scintigraphic and echocardiographic parameters (model B). RESULTS: Of the 208 patients, 56 experienced fatal cardiac events during the study. In model A, a Cox proportional hazards analysis showed baseline WR ≥50% to be the only independent predictor of cardiac death (hazard ratio=2.335, 95% confidence interval=1.142-4.774, P=0.020). In model B, delta-WR≥-5% was the only incremental predictor of cardiac death (hazard ratio=4.444, 95% confidence interval=1.511-13.069, P=0.009). The survival rates of patients with a delta-WR of less than -5% were significantly higher for those with a baseline WR of less than 50% (P=0.036). Moreover, high delta-WR was the best predictor compared with single scan, single echocardiography, and their combination evaluated by the global χ² analysis. CONCLUSION: Baseline WR and delta-WR obtained from ¹²³I-MIBG scintigraphy can be used as independent predictors of cardiac death, and two ¹²³I-MIBG scintigraphic studies are more useful than a one-time scan in stabilized patients with CHF.
No takes yet. Share an insight, caveat, or question.
Kasama et al. (2010) conducted a cohort in chronic heart failure (n=208). Serial 123I-MIBG scintigraphic studies (delta washout rate) vs. One-time 123I-MIBG scan (baseline washout rate) was evaluated on cardiac death (HR 4.444, 95% CI 1.511-13.069, p=0.009). Serial 123I-MIBG scintigraphic studies showing a delta washout rate ≥-5% strongly predicted cardiac death in stabilized chronic heart failure patients (HR 4.444; 95% CI 1.511-13.069; P=0.009).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: