Why the study?
Does residual apixaban concentration affect bleeding complications during and after catheter ablation of atrial fibrillation?
Does residual apixaban concentration affect bleeding complications during and after catheter ablation of atrial fibrillation?
Low residual plasma apixaban is associated with a higher incidence of bleeding complications during and after AF ablation, likely due to a greater heparin requirement to achieve target ACT.
May heighten bleeding risk during AF ablation; leaves open whether concentration-guided protocols improve safety.
Background The periprocedural protocol for atrial fibrillation (AF) ablation commonly includes anticoagulation therapy. Apixaban, a direct oral anticoagulant, is currently approved for clinical use; however, little is known about the effects of residual apixaban concentration on bleeding complications during/after AF ablation. Therefore, we measured residual apixaban concentration by using mass spectrometry and examined the anticoagulant's residual effects on bleeding complications. Methods Fifty‐eight patients (Mean age of 64.7±12.5 years; 31 males, 27 females) were enrolled and administered apixaban twice daily. We analyzed trough apixaban concentration, activated clotting time (ACT), heparin dose, and bleeding complications during/after AF ablation. Apixaban concentrations were directly measured using mass spectrometry. Results Bleeding complications were observed in 19 patients (delayed hemostasis at the puncture site, 16; hematuria, 3; hemosputum, 1). No patient required blood transfusion. The mean trough apixaban concentration was significantly lower in patients with bleeding complications than without (152.4±73.1 vs. 206.8±98.8 ng/mL respectively, P =0.037), while the heparin dose to achieve ACT>300 s was significantly higher in patients with bleeding complications (9368.4±2929.0 vs. 7987.2±2135.2 U/body respectively, P =0.046). Interestingly, a negative correlation was found between the trough apixaban concentration and the heparin dose to achieve ACT>300 s ( P =0.033, R=‐0.281). Conclusions Low residual plasma apixaban is associated with a higher incidence of bleeding complications during/after AF ablation, potentially because of a greater heparin requirement during AF ablation.
No takes yet. Share an insight, caveat, or question.
Mukai et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: